GE CT9070SHSS Installation Instructions - Page 2
Cutout For Installation Over A Warming Drawer, Cutout For Single Ovens In Wall Cabinet - wall oven
View all GE CT9070SHSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
2 A CUTOUT FOR SINGLE OVENS IN WALL CABINET NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick, shim both sides equally to establish the cutout width. These ovens are not approved for stackable installations. E Opening J Between Inside Walls Must be at Least 281ø2" (72.4 cm) Wide H Junction Box Location (junction box may be located in adjacent cabinet) D 22" (55.9 J cm) Min. to Bottom of Junction Box Cutout Depth 231ø " 2 (59.7 cm) Min. B F C G Recommended Cutout Location from Floor 321ø " (82.6 cm) 161ø24" (41.3 cm) Min. 2 B CUTOUT FOR INSTALLATION OVER A WARMING DRAWER NOTE: Install the oven only with specific models listed on the label located on top of the oven. NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly grounded receptacle must be installed. Refer to installation instructions packed with the Warming Drawer for specific installation requirements. Anti-Tip Block Against Rear Wall Per Warming Drawer Requirement 2" (5.1 cm) Min. Side-by-Side Installations Install two ovens in separate cutouts. Center Line Center Line 30" Models 581ø " (148.6 cm) if both ovens are French Door 421ø22" (108 cm) if only one oven is French Door Cutout - observe all dimensions and requirements. Cutout - observe all dimensions and requirements. K 30" (76.2 cm) Min. if both ovens are French Door 14" (35.6 cm) Min. if only one oven is French Door A L C E E Dimension A B C D E F G H J K L Dimension Description Cabinet width Cutout width Cutout height Overlap of oven over side edges of cutout Door swing depth - Allow additional clearances for installation and oven usage Overlap of oven top of cutout Overlap of oven bottom of cutout Junction box location Door swing width - Allow additional clearances for installation and oven usage Countertop or cabinet door protrusion (measure if exist) Gap between edge of countertop or cabinet door to cabinet opening 30" Single Oven 30" (76.2 cm) 228851øø82"" (72.4 (72.7 cm) cm) min. max. 227751ø ø4"" (69.2 (69.4 cm) cm) min. max. 16 11ø16" (1.75 cm) 161ø4" (41.3 cm) min. 1" (2.5 cm) min. 11ø " (3.2 cm) 4 91ø " (24.1 cm) max. 2 right side only 14" (35.6 cm) min. Measure "K" If K = 0, L = 0, Otherwise L = K + 1" (2.54 cm) min. Per Warming Drawer Requirement