GE DCVH680GJMV Installation Instructions - Page 6
Installation Instructions, Exhausting
UPC - 084691208921
View all GE DCVH680GJMV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Installation Instructions, Exhausting CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT • For best drying performance, a rigid metal transition duct is recommended. • Rigid metal transitions ducts reduce the risk of crushing and kinking. UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT • If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). • Never install flexible metal duct in walls, ceilings, floors or other enclosed spaces. • Total length of flexible metal duct should not exceed 8 feet (2.4m). • For many applications, installing elbows at both the dryer and the wall is highly recommended (see illustrations below). Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct, maximizing drying performance. • Avoid resting the duct on sharp objects. UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT • In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil- type) duct. A UL-listed flexible metal (foil-type)duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length of the transition duct. • In Canada and the United States, only the flexible metal(foiltype) ducts that comply with the "Outline for Clothes Dryer Transition Duct Subject 2158A" shall be used. • Never install flexible metal duct in walls, ceilings, floors or other enclosed spaces. • Total length of flexible metal duct should not exceed 8 feet (2.4m). • Avoid resting the duct on sharp objects. • For best drying performance: 1. Slide one end of the duct over the clothes dryer outlet pipe. 2. Secure the duct with a clamp. 3. With the dryer in its permanent position, extend the duct to its full length. Allow 2" of duct to overlap the exhaust pipe. Cut off and remove excess duct. Keep the duct as straight as possible for maximum airflow. 4. Secure the duct to the exhaust pipe with the other clamp. DO DO NOT USE EXCESSIVE EXHAUST LENGTH DON'T DO NOT SIT DRYER ON FLEXIBLE EXHAUST. DO NOT CRUSH FLEXIBLE EXHAUST AGAINST WALL. 9 ALCOVE OR CLOSET INSTALLATION • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be vented to the outdoors. See the EXHAUST INFORMATION section. • Minimum clearance between dryer cabinet and adjacent walls or other surfaces is: 0 in. either side 3 in. front and rear • Minimum vertical space from floor to overhead cabinets, ceiling, etc. is 43 in. without pedestal, 55 in. with pedestal. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 IN. 10 BATHROOM OR BEDROOM INSTALLATION • The dryer MUST be vented to the outdoors. See EXHAUST INFORMATION section 6. • The installation must conform with local codes or, in the absence of local codes, with the NATIONAL FUEL GAS CODE, ANSI Z223. ELBOW HIGHLY RECOMMENDED ELBOWS HIGHLY RECOMMENDED 11 MOBILE OR MANUFACTURED HOME INSTALLATION • Installation must conform to the MANUFACTURED HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80 or, when such standard is not applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME, NO. 501B. • The dryer MUST be vented to the outdoors with the termina- tion securely fastened to the mobile home structure. (See EXHAUST INFORMATION section 6.) • The vent MUST NOT be terminated beneath a mobile or manufactured home. • The vent duct material MUST BE METAL. • KIT 14-D346-33 MUST be used to attach the dryer securely to the structure. • The vent MUST NOT be connected to any other duct, vent, or chimney. • Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent. • Provide an opening with a free area of at least 25 sq. in. for 6 introduction of outside air into the dryer room.