Genie PowerLift Owner's Manual - Page 21
Installation Step 10
View all Genie PowerLift manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
NOTE • To protect your new investment, your Excelerator® is equipped with a Timer and Cycle Counter which work together to prevent any chance of heat damage to electrical circuits caused by too many cycles in too short a time. If your Opener suddenly stops responding to the Wall Console - Do Not Unplug the Unit - simply wait 10 minutes for the Timer/Cycle Counter to reset itself and try again. • Unplugging the unit will prevent the Timer/Cycle Counter from resetting. D Test Door Opener: • Run door up and down a few times using Wall Console and observe door travel. • Repeat steps above as needed to set Limit Switch positions. E Adjust Open Force to minimum needed: • Place door in closed position using Wall Console. • Gently adjust Open Force fully counterclockwise (minimum force). • Run Opener using Wall Console. • Observe that door runs to Open Limit Switch. - If not, adjust Open Force Control slightly clockwise, close garage door, and open it again. • Repeat steps above until garage door runs smoothly from Close Limit Switch to Open Limit Switch. F Adjust Close Force to minimum needed: • Place door in open position using Wall Console. • Gently adjust Close Force fully counterclockwise (minimum force). • Run Opener using Wall Console. • Observe that door runs to Close Limit Switch. - If not, adjust Close Force Control slightly clockwise, open garage door, and close it again. • Repeat steps above until garage door runs smoothly from Open Limit Switch to Close Limit Switch. Installation SteCpH10: SETTING CONTACT REVERSE FUNCTION NOTE Limit Switch and Force Adjustments must be completed before checking the contact reverse function (Figure 36). A Open garage door using Wall Console. B Lay a 2" x 4" board flat in center of doorway. C Close door using Wall Console. D Check that door stops and reverses within 2 seconds after it contacts board: • If door does not reverse, decrease Close Force until door reverses. • If door still does not reverse, move Limit Switch toward door. E Check Safe-T-Beam® System operation: • If beam is blocked, door will not close. NOTE The door must contact the 2" x 4" board before the Carriage activates the Close Limit Switch. If not, readjust the Close Limit Switch. 2" x 4" board laid flat Figure 36 Checking Contact Reverse For Help, call 1-800-35-GENIE or visit www.geniecompany.com 21