Gigabyte GA-G41MT-S2PT Manual - Page 23

Memory Frequency Mhz, DRAM Timing Selectable SPD, CAS Latency Time, Command RateCMD

Page 23 highlights

Memory Frequency (Mhz) The first memory frequency value is the normal operating frequency of the memory being used; the second is the memory frequency that is automatically adjusted according to the System Memory Multiplier settings. DRAM Timing Selectable (SPD) Manual allows all DRAM timing control items below to be configurable. Options are: Auto (default), Manual. >>>>> Standard Timing Control CAS Latency Time Options are: Auto (default), 4~11. tRCD Options are: Auto (default), 1~15. tRP Options are: Auto (default), 1~15. tRAS Options are: Auto (default), 1~63. >>>>> Advanced Timing Control Advanced Timing Control CMOS Setup Utility-Copyright (C) 1984-2011 Award Software Advanced Timing Control x tRRD x tWTR x tWR x tRFC x tRTP x Command Rate (CMD) Auto Auto Auto Auto Auto Auto Item Help Menu Level  >>>>> Channel A } Channel A Timing Settings } Channel A Driving Settings [Press Enter] [Press Enter] >>>>> Channel B } Channel B Timing Settings } Channel B Driving Settings [Press Enter] [Press Enter] Move Enter: Select F5: Previous Values +/-/PU/PD: Value F10: Save F6: Fail-Safe Defaults tRRD Options are: Auto (default), 1~15. tWTR Options are: Auto (default), 1~31. tWR Options are: Auto (default), 1~31. tRFC Options are: Auto (default), 1~255. tRTP Options are: Auto (default), 1~15. Command Rate(CMD) Options are: Auto (default), 1~3. ESC: Exit F1: General Help F7: Optimized Defaults - 23 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

- 23 -
Memory Frequency (Mhz)
The first memory frequency value is the normal operating frequency of the memory being used; the
second is the memory frequency that is automatically adjusted according to the
System Memory Multi-
plier
settings.
DRAM Timing Selectable (SPD)
Manual
allows all DRAM timing control items below to be configurable. Options are: Auto (default),
Manual.
>>>>>
Standard Timing Control
CAS Latency Time
Options are: Auto (default), 4~11.
tRCD
Options are: Auto (default), 1~15.
tRP
Options are: Auto (default), 1~15.
tRAS
Options are: Auto (default), 1~63.
CMOS Setup Utility-Copyright (C) 1984-2011 Award Software
Advanced Timing Control

: Move
Enter: Select
+/-/PU/PD: Value
F10: Save
ESC: Exit
F1: General Help
F5: Previous Values
F6: Fail-Safe Defaults
F7: Optimized Defaults
Item Help
Menu Level

x
tRRD
Auto
x
tWTR
Auto
x
tWR
Auto
x
tRFC
Auto
x
tRTP
Auto
x
Command Rate (CMD)
Auto
>>>>>
Channel A
Channel A Timing Settings
[Press Enter]
Channel A Driving Settings
[Press Enter]
>>>>>
Channel B
Channel B Timing Settings
[Press Enter]
Channel B Driving Settings
[Press Enter]
tRRD
Options are: Auto (default), 1~15.
tWTR
Options are: Auto (default), 1~31.
tWR
Options are: Auto (default), 1~31.
tRFC
Options are: Auto (default), 1~255.
tRTP
Options are: Auto (default), 1~15.
Command Rate(CMD)
Options are: Auto (default), 1~3.
>>>>>
Advanced Timing Control
Advanced Timing Control