Gigabyte GA-P55-USB3 Manual - Page 105

For the GIGABYTE SATA2, Rebuilding with the RAID setup utility, Main Menu, Rebuild Mirror Drive,

Page 105 highlights

For the GIGABYTE SATA2: Turn off your computer and replace the failed hard drive with a new one. Use either the RAID setup utility or the GIGABYTE RAID CONFIGURER utility in the operating system to perform the rebuild. • Rebuilding with the RAID setup utility Step 1: When the message "Press to enter RAID Setup Utility" appears, press + to enter the utility. In the Main Menu block, select Rebuild Mirror Drive and press . The selection bar will move to the degraded array. Press again. [ Main Menu ] Create RAID Disk Drive Delete RAID Disk Drive Revert HDD to Non-RAID Solve Mirror Conflict Rebuild Mirror Drive Save And Exit Setup Exit Without Saving Gigabyte Technology Corp. RAID Setup Utility v1.07.06 [ Hard Disk Drive List ] Model Name HDD0: ST3120026AS HDD1: ST3120026AS Capacity 120 GB 120 GB Type/Status RAID Inside Non-RAID [ RAID Disk Drive List ] Model Name RDD0: GRAID RAID Level 1-Mirror Capacity 120 GB Status Degraded Members(HDDx) 0? [fgTAB]-Switch Window [hi]-Select RAID [ENTER]-Action [ESC]-Exit Step 2: The selection bar will then move to new hard drive in the Hard Disk Drive List block. Press to start the RAID rebuilding process. The rebuilding progress is displayed at the bottom of the screen. When done, the status of the array will display as Normal. Gigabyte Technology Corp. RAID Setup Utility v1.07.06 [ Main Menu ] Create RAID Disk Drive Delete RAID Disk Drive Revert HDD to Non-RAID Solve Mirror Conflict Rebuild Mirror Drive Save And Exit Setup Exit Without Saving [ Hard Disk Drive List ] Model Name HDD0: ST3120026AS HDD1: ST3120026AS Capacity 120 GB 120 GB Type/Status RAID Inside Non-RAID [ RAID Disk Drive List ] Model Name RDD0: GRAID RAID Level 1-Mirror Capacity 120 GB Status Degraded Members(HDDx) 0? Rebuilding....35%, please wait.... - 105 - Appendix

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

- 105 -
Appendix
For the GIGABYTE SATA2:
Turn off your computer and replace the failed hard drive with a new one. Use either the RAID setup utility or
the GIGABYTE RAID CONFIGURER utility in the operating system to perform the rebuild.
Rebuilding with the RAID setup utility
Step 1:
When the message "Press <Ctrl-G> to enter RAID Setup Utility" appears, press <Ctrl> + <G> to enter the util-
ity. In the
Main Menu
block, select
Rebuild Mirror Drive
and press <Enter>. The selection bar will move to
the degraded array. Press <Enter> again.
Step 2:
The selection bar will then move to new hard drive in the
Hard Disk Drive List
block. Press <Enter> to start
the RAID rebuilding process. The rebuilding progress is displayed at the bottom of the screen. When done,
the status of the array will display as
Normal
.
Model Name
RAID Level
Capacity
Status
Members(HDDx)
RDD0: GRAID
1-Mirror
120 GB
Degraded
0?
[
fg
TAB]-Switch Window
[
hi
]-Select RAID
[ENTER]-Action
[ESC]-Exit
[ RAID Disk Drive List ]
[ Main Menu ]
[ Hard Disk Drive List ]
Gigabyte Technology Corp.
RAID Setup Utility
v1.07.06
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
Solve Mirror Conflict
Rebuild Mirror Drive
Save And Exit Setup
Exit Without Saving
Model Name
Capacity
Type/Status
HDD0: ST3120026AS
120 GB
RAID Inside
HDD1: ST3120026AS
120 GB
Non-RAID
Model Name
RAID Level
Capacity
Status
Members(HDDx)
RDD0: GRAID
1-Mirror
120 GB
Degraded
0?
Rebuilding
....
35%, please wait
....
[ RAID Disk Drive List ]
[ Main Menu ]
[ Hard Disk Drive List ]
Gigabyte Technology Corp.
RAID Setup Utility
v1.07.06
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
Solve Mirror Conflict
Rebuild Mirror Drive
Save And Exit Setup
Exit Without Saving
Model Name
Capacity
Type/Status
HDD0: ST3120026AS
120 GB
RAID Inside
HDD1: ST3120026AS
120 GB
Non-RAID