TROUBLESHOOTING/ ILLUSTRATIONS AND ELECTRICAL DRAWINGS CAUSE 3. SYSTEM A. PRESSURE REQUIRED BY SYSTEM AT DESIGN FLOW RATE EXCEEDS PRESSURE RATING OF PUMP B. OBSTRUCTION IN SUCTION PIPING C. PRESSURE RATING OF PUMP EXCEEDS PRESSURE REQUIREMENT OF SYSTEM AT DESIGN FLOW RATE D. SUCTION LIFT EXCEEDS 10'DESIGN MAXIMUM CORRECTIVE ACTION Compare pump pressure and flow rate against pump characteristic curve. Check for closed or partially closed valve in discharge piping system. Reduce system pressure requirement. Increase pressure capability of pump. Locate and remove obstruction. Compare pump pressure and flow rate against pump characteristic curve. Inspect discharge piping system for breaks, leaks, open by-pass valves, etc. If necessary, reduce flow rate by partially closing discharge valve. Locate pump closer (vertically) to water source. 12. Illustrations and Electrical Drawings Figure 1 20" 10" 20" 4" Figure 2 - 230V Connection Figure 3 - 460V Connection 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

TROUBLESHOOTING/ ILLUSTRATIONS AND ELECTRICAL DRAWINGS
22
Figure 2 - 230V Connection
12. Illustrations and Electrical Drawings
Figure 1
Figure 3 - 460V Connection
CAUSE
CORRECTIVE ACTION
3. SYSTEM
A.
PRESSURE REQUIRED BY SYSTEM AT
DESIGN FLOW RATE EXCEEDS
PRESSURE RATING OF PUMP
Compare pump pressure and flow rate against pump characteristic curve.
Check for closed or partially closed valve in discharge piping system.
Reduce system pressure requirement. Increase pressure capability of pump.
B. OBSTRUCTION IN SUCTION PIPING
Locate and remove obstruction.
C.
PRESSURE RATING OF PUMP EXCEEDS
PRESSURE REQUIREMENT OF SYSTEM
AT DESIGN FLOW RATE
Compare pump pressure and flow rate against pump characteristic curve.
Inspect discharge piping system for breaks, leaks, open by-pass valves, etc.
If necessary, reduce flow rate by partially closing discharge valve.
D.
SUCTION LIFT EXCEEDS
10'DESIGN MAXIMUM
Locate pump closer (vertically) to water source.
10"
4"
20"
20"