Hayward HYDRAPURE HydraPure Owners Manual

Hayward HYDRAPURE Manual

Hayward HYDRAPURE manual content summary:

  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 1
    101950175500 - R00 HydraPure 2½ inch Residential AOP System Owner's Manual Contents Overview 3 Installation 4 Operation 8 HYDRAPURE Hayward Industries 400 Connell Drive, Suite 6100 Berkeley Heights, NJ 07922 Phone: (908) 355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 2
    servicing the unit. •  WARNING: To reduce the risk of electric shock, injury or death disconnect unit from power supply. • WARNING: Follow the instructions . SAVE THESE INSTRUCTIONS Signal Words and Symbols Used In This Manual This Owner's Manual and Installation Guide contains specific precautions
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 3
    REVIEW THE OWNER'S MANUAL AND INSTALLATION GUIDE IN ITS ENTIRETY AND HEED ALL SAFETY INFORMATION. Failure to follow these instructions and warnings can result INJURY, INCLUDING DEATH. Disconnect all AC power before installation and servicing. To prevent possible fire or electrical shock, use only
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 4
    Overview Specifications Plumbing diameter: 2" Socket, 2½" SPIGOT Input power: 120VAC, 50Hz/60Hz or 240VAC, 50Hz/60Hz Power consumption: 151 Watts; or 1.26A, 120 VAC; 0.66A, 230VAC Maximum operating pressure: 50 psi Operating flow range: 10-120 gpm Maximum flow rate: 120 gpm 99.9% sanitization flow
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 5
    a great deal of time (and expense) later. If you have any questions that are unanswered when you have completed the reading of this manual, contact your supplier or Hayward. Installation of HydraPure requires mounting, plumbing, installing a venturi and flow switch (on the return side of the filter
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 6
    Plumbing the HydraPure Unit 1 Attach the (2) PVC 2½" union nuts to the unit. DO NOT OVER TIGHTEN, OVER TIGHTENING WILL CAUSE THE UNIONS TO BREAK. 2 After cutting pipes to length, debur all cut pipe to ensure shavings don't plug critical points internal to the unit. Use PVC solvent cement to glue
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 7
    Kit Number HYDRACORDKIT (sold separately) for 120V corded installation. Follow steps 1 & 2 below. L1 N Ground 1 Remove the lid by following the instructions on the bottom of this page. To install the HYDRACORDKIT, attach wires to connections according to the illustration above. 2 Plug HydraPure
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 8
    In some cases it may be necessary to use an alternate Ozone check valve. This prevents the HydraPure unit from losing pump prime and draining down the equipment set. This would be necessary when the HydraPure Unit is positioned with the base of the unit greater than 1' above water level. In that
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 9
    Operation No lights on unit is off Green POWER light indicates power to unit Green FLOW light indicates proper water flow into unit Yellow Green UV BULB LIFE & Yellow Green OZONE BULB LIGHT indicates all bulbs and unit functioning properly Green or red flashing UV BULB LIFE indicates UV bulb is
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 10
    Press for 1 second and then release the UV Reset button to view remaining lamp life. The UV LED will turn off, and then flash yellow once for each 1000 hours left. (9 flashes = 9000 hours remaining). Press for 1 second and then release the Ozone Reset button to view remaining lamp life. The Ozone
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 11
    6 Carefully lift the lamp assembly, including lamp holder, do not pull excessively on the lamp wires. 7 T urning counter-clockwise, unscrew the round sealing nut. 8 R emove the aluminum compression washer making sure not to lose the black gasket. NOTICE: Do not touch the glass part of the lamp
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 12
    Press down evenly 11 Grinegntmly alokwesercothnetaqcut awrtizthtuthbee into the unit until the Otop of the black threaded sealing sleeve. Then place the aluminum compression washer and gasket on the quartz tube. Press down on the aluminum compression washer with an even steady pressure. Lift
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 13
    UV Lamps Replacement WARNING: Turn off all power to the HydraPure unit and pool pump. Before proceeding allow at least 15 minutes for the lamp(s) in the unit to cool. Never remove the electrical enclosure cover without first disconnecting the power source from the HydraPure unit. Never remove the
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 14
    UV BULB LIFE Button, for a minimum of 15 seconds, to reset the lamp life indicator. Discard lamp(s) appropriately. Visit www.lamprecycle.org for instructions on disposal. Ozone Lamps Replacement WARNING: Turn off all power to the HydraPure unit and pool pump. Before proceeding allow at least 15
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 15
    and hold OZONE BULB LIFE Button, for a minimum of 15 seconds, to reset the lamp life indicator. Discard lamp(s) appropriately. Visit www. lamprecycle.org for instructions on disposal. 14 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 16
    Winterizing WARNING: Turn off all power to the HydraPure unit and pool pump before proceeding to winterize. Remove Winterizing O-ring plug near the bottom of the unit by turning counter clockwise. Note, there will be an initial rush of water from the unit after the plug is removed. Allow unit to
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 17
    Replacement Parts A table of replacement parts is shown below. Refer to the diagram on page 17 when using the table. ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NUMBER HYDRACORDKIT HYDRAMEMBRANE HYDRAPCBA HYDRAHARNESS HYDRASCREWPK HYDRAORINGS HYDRACHKVLVBP
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 18
    Replacement Parts 12 21 22 13 4 17 2 14 3 5 7 15 8 18 9 10 19 11 20 6 16 1 23 17 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 19
    This page intentionally blank 18 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
  • Hayward HYDRAPURE | HydraPure Owners Manual - Page 20
    For further information or consumer technical support, visit our website at www.hayward.com Hayward is a registered trademark of Hayward Industries, Inc. © 2022 Hayward Industries, Inc. All other trademarks not owned by
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
HydraPure
2
½
inch Residential AOP System
Owner's Manual
HYDRAPURE
Contents
Overview
................................
3
Installation
............................
4
Operation
..............................
8
101950175500 - R00
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS