UV Lamps Replacement

Page 13 highlights

UV Lamps Replacement WARNING: Turn off all power to the HydraPure unit and pool pump. Before proceeding allow at least 15 minutes for the lamp(s) in the unit to cool. Never remove the electrical enclosure cover without first disconnecting the power source from the HydraPure unit. Never remove the HydraPure unit's cover without turning off the pump. Before removing lamps, you must wear protective rubber gloves and safety eye wear. Do not handle a hot lamp or serious burns will occur. Red flashing UV BULB LIFE indicates UV bulb is no longer sanitizing and should be replaced soon, 1 Turn Off Power to unit or unplug. 2 R emove screws to lid. 4 D isconnect UV lamps from ballast. 3 R emove both screws to electrical enclosure cover. 5 R emove spring clip. 12 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

UV Lamps Replacement
WARNING:
Turn off all power to the HydraPure unit and pool pump. Before proceeding allow at least
15 minutes for the lamp(s) in the unit to cool. Never remove the electrical enclosure cover without first
disconnecting the power source from the HydraPure unit. Never remove the HydraPure unit’s cover
without turning off the pump. Before removing lamps, you must wear protective rubber gloves and
safety eye wear. Do not handle a hot lamp or serious burns will occur.
Red flashing UV BULB LIFE indicates UV bulb is no
longer sanitizing and should be replaced soon,
5
Remove spring clip.
2
Remove screws to lid.
4
Disconnect UV lamps
from ballast.
3
Remove
both screws
to electrical
enclosure
cover.
1
Turn Off Power to unit or unplug.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS