Hayward HYDRAPURE HydraPure Owners Manual - Page 15
OZONE BULB LIFE Button, for a minimum
View all Hayward HYDRAPURE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
1 Turn Off Power to unit or unplug. 2 R emove screws to lid. 3 R emove both screws to electrical enclosure cover. 4 D isconnect Ozone lamp. 5 C arefully lift the lamp assembly, a slight tug may be necessary to loosen the lamp from the lamp retention fingers. 6 I nsert the new lamp into lamp holder. Lamp must be aligned and seated securely in the lamp holder. 7 A fter power is restored, press and hold OZONE BULB LIFE Button, for a minimum of 15 seconds, to reset the lamp life indicator. Discard lamp(s) appropriately. Visit www. lamprecycle.org for instructions on disposal. 14 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5
Carefully lift the lamp assembly, a slight
tug may be necessary to loosen the lamp
from the lamp retention fingers.
6
Insert the new lamp into lamp holder.
Lamp must be aligned and seated
securely in the lamp holder.
7
After power is restored, press and hold
OZONE BULB LIFE Button, for a minimum
of 15 seconds, to reset the lamp life
indicator.
Discard lamp(s) appropriately. Visit www.
lamprecycle.org for instructions on disposal.
4
Disconnect Ozone
lamp.
2
Remove screws to lid.
3
Remove
both screws
to electrical
enclosure
cover.
1
Turn Off Power to unit or unplug.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS