Hayward TriStar VS 950 2.70 THP VS Pump Family - Owners Manual - Page 21
Diagnostic Menu, Stop/Resume, Quick Clean
View all Hayward TriStar VS 950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Diagnostic Menu Screen 1. Diagnostic Menu Press > to enter Buttons Used < > Comments Use > button to enter Diagnostic Menu and toggle between displays. 2. Press > to view next item 3. Display Revision 1.03 Displays firmware version of the display PCB. 4. Drive Serial Number DET-3581200032 Displays motor drive serial number. 5. Comm Rev: 2.15 Drv Rev: 2.00.oz Displays firmware revisions of the motor drive and drive interface PCBs. 6. SVRS Revision: 1.00 Status: Monitoring Displays revision and status of integrated SVRS, if applicable. 7. Event Log Press > to view < > Use > button to view event log. NOTE: For troubleshooting purposes, the Event Log will record the last twenty error/trip conditions and/or status messages, as well as the amount of time that has elapsed since the condition occurred. See page 25 for more detail. Stop/Resume Screen 1. Pump is stopped; press Stop/Resume 2. again to resume normal operation NOTE: When Stop/Resume is pressed at any time during normal operation, the above message will be displayed. The pump will stop within several seconds, and will remain stopped until Stop/Resume is pressed a second time, at which point the pump will resume normal operation. Quick Clean Screen SVRS inactive in 1. Quick Clean mode 20 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS