HP 2000fc HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, - Page 126

Configuration using Application Templates, Cancel

Page 126 highlights

• The minimum and maximum number of disk drives for each RAID level are as follows RAID Level Minimum Drives Maximum Drives 0 2 16 1 2 16 5 3 16 6 4 16 To configure a subsystem using a customized storage deployment: 1. Start the Storage Deployment wizard automatically or manually as follows: • Automatic: If, when you start Simple SAN Connection Manager, it detects either an uninitialized EVA storage subsystem or an MSA storage subsystem that does not have any subsystem or LUN created, a message box prompts you to configure the subsystem. To start the Storage Deployment wizard, click Yes. • Manual: Follow these steps to manually start the wizard: a. On the Advanced Operations menu, click Configuration using Application Templates. b. If you have multiple subsystems, the Select a Subsystem dialog box prompts you to select the storage subsystem you want to configure. Select your subsystem, and then click OK. If the selected subsystem already has logical disks containing data, Simple SAN Connection Manager displays a message warning that the storage subsystem will be uninitialized and all logical disks and their data will be deleted. c. To acknowledge the warning, uninitialize the storage subsystem, delete all logical disks, and start the Storage Deployment wizard, type YES, and then click OK. To abandon this deployment, click Cancel. Simple SAN Connection Manager loads the storage templates and launches the wizard. If the storage subsystem is an HP EVA, the window shown in Figure 98 opens; proceed with step 2. If the storage subsystem is an HP MSA, this wizard window is not shown; skip to step 3. Figure 98 Storage Deployment wizard: enter EVA array name (custom deployment) 2. In the Enter a name to initialize the array box, type a name for the EVA storage subsystem, and then click Next. Valid names are a maximum of 32 alphanumeric characters, and may contain spaces, underscores, and special characters. 126 Managing storage subsystems

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150

126
Managing storage subsystems
The minimum and maximum number of disk drives for each RAID level are as follows
To configure a subsystem using a customized storage deployment:
1.
Start the Storage Deployment wizard automatically or manually as follows:
Automatic: If, when you start Simple SAN Connection Manager, it detects either an uninitialized
EVA storage subsystem or an MSA storage subsystem that does not have any subsystem or LUN
created, a message box prompts you to configure the subsystem. To start the Storage Deployment
wizard, click
Yes
.
Manual: Follow these steps to manually start the wizard:
a.
On the Advanced Operations menu, click
Configuration using Application Templates
.
b.
If you have multiple subsystems, the Select a Subsystem dialog box prompts you to select the
storage subsystem you want to configure. Select your subsystem, and then click
OK
.
If the selected subsystem already has logical disks containing data, Simple SAN Connection
Manager displays a message warning that the storage subsystem will be uninitialized and all
logical disks and their data will be deleted.
c.
To acknowledge the warning, uninitialize the storage subsystem, delete all logical disks, and
start the Storage Deployment wizard, type
YES,
and then click
OK
. To abandon this deployment,
click
Cancel
.
Simple SAN Connection Manager loads the storage templates and launches the wizard. If the storage
subsystem is an HP EVA, the window shown in
Figure 98
opens; proceed with
step 2
. If the storage
subsystem is an HP MSA, this wizard window is not shown; skip to
step 3
.
Figure 98
Storage Deployment wizard: enter EVA array name (custom deployment)
2.
In the Enter a name to initialize the array box, type a name for the EVA storage subsystem, and then
click
Next
. Valid names are a maximum of 32 alphanumeric characters, and may contain spaces,
underscores, and special characters.
RAID Level
Minimum Drives
Maximum Drives
0
2
16
1
2
16
5
3
16
6
4
16