HP 2000fc HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, - Page 61

Emergency, Alert, Critical, Error, Warning, Notify, Info, Debug, and Mark., Write Community

Page 61 highlights

Read Community Enter the Read Community password (maximum 32 characters) that authorizes an SNMP agent to read information from the switch. This is a write-only field. The value on the switch and the SNMP management server must be the same. The default is public. Write Community Enter the Write Community password (maximum 32 characters) that authorizes an SNMP agent to write information to the switch. This is a write-only field. This value on the switch and the SNMP management server must be the same. The default is private. SNMP Proxy Select this check box to allow the use of SNMP to monitor and configure any switch in the fabric. Clear this check box to prevent this function. Location Enter a name (maximum 64 characters) for the switch location. Authentication Trap Allows reporting of SNMP authentication failures. In the event of an authentication failure caused by incorrect community string values, a notification trap is sent to the configured trap addresses. Click True to enable this feature, or click False to disable this feature. The default value is False. The lower portion of the SNMP Properties dialog box contains tabs for each SNMP Trap Configuration, which define how each of the five traps are set. 3. For Trap 1, complete the following configuration settings: Trap Enabled Trap Version Trap Address (see note below) Trap Community Trap Severity Trap Port (see note below) Select this check box to enable this trap. Clear this check box to disable this trap (traps are not sent to trap monitoring stations and you cannot configure a disabled trap). Select the SNMP version (V1 or V2) with which to format the traps. Enter the IPv4 or IPv6 address, or DNS host name, to which SNMP traps are sent. A maximum of five trap addresses are allowed, if the firmware on the switch supports the trap community string per trap enhancement. The default address for Trap 1 is 10.0.0.254. The default address for Traps 2 through 5 is 0.0.0.0. Enter the Trap Community password that authorizes an SNMP agent to receive traps. This is a write-only field. The value on the switch and the SNMP management server must be the same. The default is public. You may enter up to 32 characters. Note that for switches running 7.4 or newer firmware, the Trap Community string is now per-trap. With firmware older than 7.4, there is just one Trap Community string for all SNMP configuration. Select a severity level to assign to the trap. Trap severity levels include Unknown, Emergency, Alert, Critical, Error, Warning, Notify, Info, Debug, and Mark. Enter the number (1-65535) of the port on which a trap is set. NOTE: The Trap Address (other than 0.0.0.0) and Trap Port combination must be unique. For example, if Trap 1 and Trap 2 have the same address, they must have different port values. Similarly, if Trap 1 and Trap 2 have the same port value, they must have different addresses. However, you can have multiple trap destinations with the same address, if you ensure that the port values are different. You can accomplish this via clish (command line interface shell) using a two-step process. First, set the address to something unique, modify the port, and save/activate. Second, go back in and set the address to one that is already set as a different trap destination. 4. To set additional traps, click the Trap 2 through Trap 5 tabs to bring each of those tabbed pages to the front and complete the settings on those pages (for details, refer to step 3). 5. To save the switch SNMP configuration settings and close this dialog box, click OK. To close the dialog box without making any changes, click Cancel. HP StorageWorks Simple SAN Connection Manager user guide 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150

HP StorageWorks Simple SAN Connection Manager user guide
61
The lower portion of the SNMP Properties dialog box contains tabs for each SNMP Trap Configuration,
which define how each of the five traps are set.
3.
For Trap 1, complete the following configuration settings:
NOTE:
The Trap Address (other than 0.0.0.0) and Trap Port combination must be unique. For
example, if Trap 1 and Trap 2 have the same address, they must have different port values.
Similarly, if Trap 1 and Trap 2 have the same port value, they must have different addresses.
However, you can have multiple trap destinations with the same address, if you ensure that the port
values are different. You can accomplish this via clish (
c
ommand
l
ine
i
nterface
sh
ell) using a
two-step process. First, set the address to something unique, modify the port, and save/activate.
Second, go back in and set the address to one that is already set as a different trap destination.
4.
To set additional traps, click the
Trap 2
through
Trap 5
tabs to bring each of those tabbed pages to the
front and complete the settings on those pages (for details, refer to
step 3
).
5.
To save the switch SNMP configuration settings and close this dialog box, click
OK
. To close the dialog
box without making any changes, click
Cancel
.
Read Community
Enter the Read Community password (maximum 32 characters) that authorizes
an SNMP agent to read information from the switch. This is a write-only field.
The value on the switch and the SNMP management server must be the same.
The default is
public
.
Write Community
Enter the Write Community password (maximum 32 characters) that authorizes
an SNMP agent to write information to the switch. This is a write-only field. This
value on the switch and the SNMP management server must be the same. The
default is
private
.
SNMP Proxy
Select this check box to allow the use of SNMP to monitor and configure any
switch in the fabric. Clear this check box to prevent this function.
Location
Enter a name (maximum 64 characters) for the switch location.
Authentication Trap
Allows reporting of SNMP authentication failures. In the event of an
authentication failure caused by incorrect community string values, a notification
trap is sent to the configured trap addresses. Click
True
to enable this feature, or
click
False
to disable this feature. The default value is False.
Trap Enabled
Select this check box to enable this trap. Clear this check box to disable this trap
(traps are not sent to trap monitoring stations and you cannot configure a
disabled trap).
Trap Version
Select the SNMP version (V1 or V2) with which to format the traps.
Trap Address
(see note below)
Enter the IPv4 or IPv6 address, or DNS host name, to which SNMP traps are
sent. A maximum of five trap addresses are allowed, if the firmware on the switch
supports the trap community string per trap enhancement. The default address
for Trap 1 is 10.0.0.254. The default address for Traps 2 through 5 is 0.0.0.0.
Trap Community
Enter the Trap Community password that authorizes an SNMP agent to receive
traps. This is a write-only field. The value on the switch and the SNMP
management server must be the same. The default is
public
. You may enter up to
32 characters.
Note that for switches running 7.4 or newer firmware, the Trap Community string
is now per-trap. With firmware older than 7.4, there is just one Trap Community
string for all SNMP configuration.
Trap Severity
Select a severity level to assign to the trap. Trap severity levels include Unknown,
Emergency, Alert, Critical, Error, Warning, Notify, Info, Debug, and Mark.
Trap Port
(see note below)
Enter the number (1–65535) of the port on which a trap is set.