HP 273914-B21 Smart Array 6400 Series Controllers User Guide - Page 29
Setting drive rebuild, expand priority, and accelerator ratio, Drive rebuild, Priority settings, Enter
UPC - 613326361313
View all HP 273914-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Configuring an array 29 − If the controller is connected to at least one logical drive, CPQONLIN continues in manual configuration mode. Use the arrow and Enter keys to navigate around the screen and set up the logical drive. To get online help at any time, press the F1 key. 5. When you have finished configuring the array, save the changes. NOTE: Newly created logical drives are invisible to the operating system. To make the new logical drives available for data storage, format them using the instructions given in the operating system documentation. The following sections provide details of some typical procedures. Setting drive rebuild, expand priority, and accelerator ratio 1. Go to the Main Configuration View screen. 2. Highlight the controller. 3. Select the Controller Settings option below Controller Options. The Controller Settings screen appears. Drive rebuild Drive rebuild occurs after a physical drive fails and is replaced. Only logical drives configured for fault tolerance (RAID 1, RAID 5, ADG) on the array with the failed physical drive will rebuild. Priority settings To set the drive rebuild priority: 1. Highlight the controller. 2. Select the controller settings: − If you choose low priority for drive rebuild, drive rebuilding occurs when I/O to the drive is inactive. − If you choose high priority, drive rebuilding occurs faster, at the expense of normal I/O operations.