HP Cisco MDS 9134 Cisco MDS 9200 Series Hardware Installation Guide (OL-16188- - Page 122

Module Specifications

Page 122 highlights

Module Specifications Appendix B Technical Specifications Table B-2 lists the physical specifications for the Cisco MDS 9200 Series. Table B-2 Physical Specifications for the Cisco MDS 9200 Series Description Specification Dimensions (HxWxD) 5.25 x 17.5 x 22.75 in. (13.3 x 44.5 x 57.8 cm) Chassis requires 3 RU1. Chassis depth including cable guide is 27.75 in. (70.3 cm). Weight Chassis only: 31 lb (14.1 kg). Chassis configured with one supervisor module, fan module, and two power supplies: 53.3 lb (24.3 kg). Power supply 845-W AC input for each power supply Airflow 300 lfm2 through system fan module, or 80 cfm3 per supervisor, switching, or services module. Total of 160 cfm if slot 2 is filled. Spacing requirements: • If installed in a cabinet, a minimum of 2.5 in. (6.4 cm) is required between the chassis air vents and the cabinet walls. • If installed in an open rack (no side panels), the horizontal distance required between the chassis and any devices that exhaust air towards the chassis is a minimum of 6 in. (15.2 cm), and the distance required between the chassis air vents and any walls is a minimum of 2.5 in. (6.4 cm). 1. RU = rack unit; 1 RU = 1.75 inches (4.45 cm) 2. lfm = linear feet per minute 3. cfm = cubic feet per minute Table B-3 lists the specifications for the Cisco MDS 9200 Series supervisor module (which is fixed in the chassis) and the switching and services modules. Module Specifications This section provides the Cisco MDS 9200 Series module specifications. Table B-3 Cisco MDS 9200 Series Module Specifications Description Specification Environmental Requirements Temperature, certified for operation 32 to 104°F (0 to 40°C) Temperature, designed and tested 32 to 130°F (0 to 55°C) for operation Temperature, ambient nonoperating -40 to 167°F (-40 to 75°C) and storage Humidity (RH), ambient (noncondensing) operating 10 to 90% Altitude, certified for operation 0 to 6500 ft (0 to 2000 m) Cisco MDS 9200 Series Hardware Installation Guide B-2 OL-16188-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

B-2
Cisco MDS 9200 Series Hardware Installation Guide
OL-16188-01
Appendix B
Technical Specifications
Module Specifications
Table B-2
lists the physical specifications for the Cisco MDS 9200 Series.
Table B-3
lists the specifications for the Cisco MDS 9200 Series supervisor module (which is fixed in
the chassis) and the switching and services modules.
Module Specifications
This section provides the Cisco MDS 9200 Series module specifications.
Table B-2
Physical Specifications for the Cisco MDS 9200 Series
Description
Specification
Dimensions
(HxWxD)
5.25 x 17.5 x 22.75 in. (13.3 x 44.5 x 57.8 cm)
Chassis requires 3 RU
1
.
Chassis depth including cable guide is 27.75 in. (70.3 cm).
1.
RU = rack unit; 1 RU = 1.75 inches (4.45 cm)
Weight
Chassis only: 31 lb (14.1 kg).
Chassis configured with one supervisor module, fan module, and
two power supplies: 53.3 lb (24.3 kg).
Power supply
845-W AC input for each power supply
Airflow
300 lfm
2
through system fan module, or 80 cfm
3
per supervisor,
switching, or services module. Total of 160 cfm if slot 2 is filled.
Spacing requirements:
If installed in a cabinet, a minimum of 2.5 in. (6.4 cm) is
required between the chassis air vents and the cabinet walls.
If installed in an open rack (no side panels), the horizontal
distance required between the chassis and any devices that
exhaust air towards the chassis is a minimum of 6 in.
(15.2 cm), and the distance required between the chassis air
vents and any walls is a minimum of 2.5 in. (6.4 cm).
2.
lfm = linear feet per minute
3.
cfm = cubic feet per minute
Table B-3
Cisco MDS 9200 Series Module Specifications
Description
Specification
Environmental Requirements
Temperature, certified for operation
32 to 104°F (0 to 40°C)
Temperature, designed and tested
for operation
32 to 130°F (0 to 55°C)
Temperature, ambient nonoperating
and storage
-40 to 167°F (-40 to 75°C)
Humidity (RH), ambient
(noncondensing) operating
10 to 90%
Altitude, certified for operation
0 to 6500 ft (0 to 2000 m)