HP Cisco MDS 9134 Cisco MDS 9200 Series Hardware Installation Guide (OL-16188- - Page 123

Weight of Modules, Description, Specification, Module, Weight

Page 123 highlights

Appendix B Technical Specifications Module Specifications Table B-3 Cisco MDS 9200 Series Module Specifications (continued) Description Altitude, designed and tested for operation Physical Characteristics Dimensions Weight Specification -200 to 10000 ft (-60 to 3000 m) 1.75 x15.5 x16.5 in. (4.4 x 39.4 x 41.9 cm) Note These are the maximum dimensions of faceplate and board, and include connectors on board. 8 to 11.5 lb (1.4 to 5.2 kg) Table B-4 lists the specifications for the batteries on the Cisco MDS 9000 Family Caching Services Module. Table B-4 Caching Services Module Battery Specifications Description Specification Nominal voltage 9.6 V Rated capacity Typical discharge capacity at 0.2C rate: 2100 mAh Minimum discharge capacity at 0.2C rate: 2000 mAh Minimum discharge capacity at 5C rate: 1800 mAh (1V/cell discharge cut-off) Discharge The battery is capable of continuous discharge from (41 to 140°F (5 to +60°C)at 5C-rate Charge From 32 to 59°F (0 to 15°C) at C/10 rate and from 59 to 104°F (15 to 40°C) at C/2-rate Storage temperature 32 to 95°F (0 to 35°C) Relative humidity range From 5 to 90% Weight of Modules Table B-5 lists the weight for each module in the Cisco MDS 9000 Family. Table B-5 Weight of Modules in the Cisco MDS 9000 Family Module 48-port 4-Gbps switching module 24-port 4-Gbps switching module 12-port 4-Gbps switching module 4-Port 10-Gbps switching module 32-port FC switching module 16-port FC switching module SSM Weight 11.0 lb (4.99 kg) 7.75 lb (3.5 kg) 7.5 lb (3.40 kg) 8.5 lb (3.86 kg) 9 lb (4.1 kg) 9 lb (4.1 kg) 11 lb (5 kg) OL-16188-01 Cisco MDS 9200 Series Hardware Installation Guide B-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

B-3
Cisco MDS 9200 Series Hardware Installation Guide
OL-16188-01
Appendix B
Technical Specifications
Module Specifications
Table B-4
lists the specifications for the batteries on the Cisco MDS 9000 Family Caching Services
Module.
Weight of Modules
Table B-5
lists the weight for each module in the Cisco MDS 9000 Family.
Altitude, designed and tested for
operation
-200 to 10000 ft (-60 to 3000 m)
Physical Characteristics
Dimensions
1.75 x15.5 x16.5 in. (4.4 x 39.4 x 41.9 cm)
Note
These are the maximum
dimensions of faceplate and board,
and include connectors on board.
Weight
8 to 11.5 lb (1.4 to 5.2 kg)
Table B-3
Cisco MDS 9200 Series Module Specifications (continued)
Description
Specification
Table B-4
Caching Services Module Battery Specifications
Description
Specification
Nominal voltage
9.6 V
Rated capacity
Typical discharge capacity at 0.2C rate: 2100 mAh
Minimum discharge capacity at 0.2C rate: 2000 mAh
Minimum discharge capacity at 5C rate: 1800 mAh
(1V/cell discharge cut-off)
Discharge
The battery is capable of continuous discharge from
(41 to 140°F (5 to +60°C)at 5C-rate
Charge
From 32 to 59°F (0 to 15°C) at C/10 rate and from 59
to 104°F (15 to 40°C) at C/2-rate
Storage temperature
32 to 95°F (0 to 35°C)
Relative humidity range
From 5 to 90%
Table B-5
Weight of Modules in the Cisco MDS 9000 Family
Module
Weight
48-port 4-Gbps switching module
11.0 lb (4.99 kg)
24-port 4-Gbps switching module
7.75 lb (3.5 kg)
12-port 4-Gbps switching module
7.5 lb (3.40 kg)
4-Port 10-Gbps switching module
8.5 lb (3.86 kg)
32-port FC switching module
9 lb (4.1 kg)
16-port FC switching module
9 lb (4.1 kg)
SSM
11 lb (5 kg)