HP Cisco Nexus 5000 Cisco MDS 9000 Family MIB Quick Reference (OL-18087-01, Fe - Page 46

Cisco-radius-mib, Cisco-rf-mib, Cisco-rf-supplemental-mib, Cisco-rmon-config-mib - power requirements

Page 46 highlights

Send documentation comments to [email protected] CISCO-RADIUS-MIB This MIB manages the RADIUS server. This MIB was removed in Cisco MDS SAN-OS Release 1.3(1) and replaced by CISCO-AAA-SERVER-MIB. CISCO-RF-MIB This MIB provides configuration control and status for the redundancy framework (RF) subsystem. RF provides a mechanism for logical redundancy of software functionality and is designed to support "one to one" redundancy on processor cards. RF is not intended to solve all redundancy schemes. RF is not designed to support redundant hardware, such as power supplies. Redundancy is concerned with the duplication of data elements and software functions to provide an alternative in case of failure. It is a key component to meeting 99.999 Percent availability requirements for Class 5 carrier solutions. In the scope of this MIB definition, peer software elements are redundant and redundant software elements are peers. CISCO-RF-SUPPLEMENTAL-MIB This MIB extends CISCO-RF-MIB by providing additional optional status and configuration control for redundant processor platforms. CISCO-RMON-CONFIG-MIB This MIB defines configuration extensions for some of the IETF RMON MIBs. The following terms are used throughout this MIB: A SPAN session is an association of one or more destination(s) with a set of source(s), along with other parameters, to specify the network traffic to be monitored. Each SPAN session is denoted by a unique number. A remote SPAN, also called RSPAN, refers to the analysis of network traffic remotely, from destination port(s) for one or more source ports, distributed in one or more switches in a switched network, through an RSPAN VLAN. Americas Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA © Cisco Systems, Inc. All rights reserved.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Send documentation comments to [email protected]
Americas Headquarters:
© <2009> Cisco Systems, Inc. All rights reserved.
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706
USA
CISCO-RADIUS-MIB
This MIB manages the RADIUS server. This MIB was removed in Cisco MDS SAN-OS Release 1.3(1)
and replaced by
CISCO-AAA-SERVER-MIB
.
CISCO-RF-MIB
This MIB provides configuration control and status for the redundancy framework (RF) subsystem. RF
provides a mechanism for logical redundancy of software functionality and is designed to support “one
to one” redundancy on processor cards. RF is not intended to solve all redundancy schemes. RF is not
designed to support redundant hardware, such as power supplies.
Redundancy is concerned with the duplication of data elements and software functions to provide an
alternative in case of failure. It is a key component to meeting 99.999 Percent availability requirements
for Class 5 carrier solutions.
In the scope of this MIB definition, peer software elements are redundant and redundant software
elements are peers.
CISCO-RF-SUPPLEMENTAL-MIB
This MIB extends CISCO-RF-MIB by providing additional optional status and configuration control for
redundant processor platforms.
CISCO-RMON-CONFIG-MIB
This MIB defines configuration extensions for some of the IETF RMON MIBs.
The following terms are used throughout this MIB:
A
SPAN session
is an association of one or more destination(s) with a set of source(s), along with other
parameters, to specify the network traffic to be monitored. Each SPAN session is denoted by a unique
number.
A
remote SPAN
, also called RSPAN, refers to the analysis of network traffic remotely, from destination
port(s) for one or more source ports, distributed in one or more switches in a switched network, through
an RSPAN VLAN.