HP Cisco Nexus 5000 Cisco Nexus 5000 Series Release Notes Release 4.1(3)N1(1) - Page 15

Symptom, show cfs application, Workaround, show cfs, application, no shut, shutdown

Page 15 highlights

Caveats Send documentation comments to [email protected] • CSCsm16222 Symptom: CFS does not support roles configuration distribution. Enter the show cfs application command to see the registered applications. Workaround: Any features not registered with CFS need to be configured locally on the switch. • CSCsl73766 Symptom: CFS does not support RADIUS configuration distribution. Enter the show cfs application command to see the registered applications. Workaround: Any features not registered with CFS need to be configured locally on the switch. • CSCso25966 Symptom: When an LACP port channel is configured between Catalyst 6500 and Cisco Nexus 5000 Series switches, and the configurations on both sides of the port channel do not match, the Catalyst 6500 LACP ports may change to the errordisable state. Workaround: Fix the configuration to make it consistent on both peer switches of the port channel, and perform a shut and no shut operation on the Catalyst 6500 port channel interface. • CSCso27446 Symptom: When a shutdown command is issued to the mgmt0 interface on a Cisco Nexus 5000 Series switch, the link never goes down and the remote end does not indicate that the link is down. Workaround: None. • CSCso46345 Symptom: The current version of NX-OS software running on the Cisco Nexus 5000 Series switches does not support Brocade i10K interop mode 4. The i10k v9.2.0.8 is supported by MDS in SAN-OS 3.2(2c), and 3.2(3) with interop mode 1 and 4. Workaround: None. • CSCso74872 Symptom: When two SNMP walks are started simultaneously, one of them may fail with the following error: OID not increasing This problem does not occur with a single SNMP walk. Workaround: This is not a permanent failure. Restart the walk and the problem will not occur as long as there is no other SNMP walk in progress. • CSCso84269 Symptom: Occasionally, when reload is executed after bootup, and there has been no configuration change, the switch will display the following warning: 'WARNING: There is unsaved configuration!!!' Workaround: Enter the copy running startup command. The problem will disappear. • CSCsq10026 Symptom: When the small form-factor pluggable (SFP) is not in the Ethernet port, the show interface command output displays a bandwidth of 1 Gbps. When the SFP is plugged in, the bandwidth is displayed correctly (10 Gbps). Workaround: None. OL-16601-01 Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, Release 4.1(3)N1(1) 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Send documentation comments to [email protected]
15
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, Release 4.1(3)N1(1)
OL-16601-01
Caveats
CSCsm16222
Symptom:
CFS does not support roles configuration distribution. Enter the
show cfs application
command to see the registered applications.
Workaround:
Any features not registered with CFS need to be configured locally on the switch.
CSCsl73766
Symptom:
CFS does not support RADIUS configuration distribution. Enter the
show cfs
application
command to see the registered applications.
Workaround:
Any features not registered with CFS need to be configured locally on the switch.
CSCso25966
Symptom
: When an LACP port channel is configured between Catalyst 6500 and Cisco Nexus 5000
Series switches, and the configurations on both sides of the port channel do not match, the Catalyst
6500 LACP ports may change to the errordisable state.
Workaround
: Fix the configuration to make it consistent on both peer switches of the port channel,
and perform a
shut
and
no shut
operation on the Catalyst 6500 port channel interface.
CSCso27446
Symptom
: When a
shutdown
command is issued to the mgmt0 interface on a Cisco Nexus 5000
Series switch, the link never goes down and the remote end does not indicate that the link is down.
Workaround
: None.
CSCso46345
Symptom
: The current version of NX-OS software running on the Cisco Nexus 5000 Series
switches does not support Brocade i10K interop mode 4. The i10k v9.2.0.8 is supported by MDS in
SAN-OS 3.2(2c), and 3.2(3) with interop mode 1 and 4.
Workaround
:
None.
CSCso74872
Symptom
: When two SNMP walks are started simultaneously, one of them may fail with the
following error:
OID not increasing
This problem does not occur with a single SNMP walk.
Workaround
:
This is not a permanent failure. Restart the walk and the problem will not occur as
long as there is no other SNMP walk in progress.
CSCso84269
Symptom
: Occasionally, when reload is executed after bootup, and there has been no configuration
change, the switch will display the following warning:
'WARNING: There is unsaved configuration!!!'
Workaround
: Enter the
copy running startup
command. The problem will disappear.
CSCsq10026
Symptom
: When the small form-factor pluggable (SFP) is not in the Ethernet port, the
show
interface
command output displays a bandwidth of 1 Gbps. When the SFP is plugged in, the
bandwidth is displayed correctly (10 Gbps).
Workaround
:
None.