Resolved Caveats-Cisco NX-OS Release 4.0(0)N1(2), Symptom, Workaround, no shut

Page 23 highlights

Caveats Send documentation comments to [email protected] • CSCsu32247 Symptom: The Nexus 5000 Series switch executes the power-on self-test (POST) at bootup to validate hardware integrity of the ASICs. When a Fibre Channel port is connected to a host bus adapter (HBA), the HBA driver can trigger a signal loss that causes a false failure to be reported by POST for one of the ASICs. As a result, all the ports serviced by the ASIC on the GEM are marked for hardware failure. Workaround: Do not connect HBAs to the FC expansion modules. • CSCsu40126 Symptom: When the Cisco Nexus 5000 Series switch is configured to operate in the N-port virtualization (NPV) mode, the LOGOs received over the server port are not processed properly. This results in stale Fibre Channel IDs at the switch. Workaround: Perform shut and no shut command operations on all the server ports to clear the stale state on the NPV switch. • CSCsm66194 and CSCsr66209 Symptom: Logins may not be uniformly balanced across all available border ports when the Cisco Nexus 5000 Series switch operates in the NPV mode under conditions such as the following: • The switch is reloaded. • NPIV is disabled and re-enabled on the NPV core-switch. • The NPV core-switch is reloaded. • A new NP link is added. Workaround: Perform shut and no shut command operations on all the server ports to rebalance the logins. • CSCsu25775 Symptom: When the Cisco Nexus 5020 Series switch is connected to a 110 V power supply, the following problems occur: • The syslog displays warnings at bootup. Although the hardware supports the 110 V input, the operating system incorrectly logs the warning message. • The show environment power command incorrectly displays the available power as a negative value. Workaround: The problem is not significant and the system operates normally with 110 V power supply input. There is no workaround to avoid the syslog message. Resolved Caveats-Cisco NX-OS Release 4.0(0)N1(2) This section lists the resolved caveats for this release. • CSCsq61505 Symptom: Problems are encountered while upgrading to Cisco NX-OS Release 4.0(0)N1(2) from Cisco NX-OS Releases 4.0(0)N1(1) or 4.0(0)N1(1a). Workaround: None. OL-16601-01 Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, Release 4.1(3)N1(1) 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Send documentation comments to [email protected]
23
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes, Release 4.1(3)N1(1)
OL-16601-01
Caveats
CSCsu32247
Symptom
: The Nexus 5000 Series switch executes the power-on self-test (POST) at bootup to
validate hardware integrity of the ASICs. When a Fibre Channel port is connected to a host bus
adapter (HBA), the HBA driver can trigger a signal loss that causes a false failure to be reported by
POST for one of the ASICs. As a result, all the ports serviced by the ASIC on the GEM are marked
for hardware failure.
Workaround:
Do not connect HBAs to the FC expansion modules.
CSCsu40126
Symptom
: When the Cisco Nexus 5000 Series switch is configured to operate in the N-port
virtualization (NPV) mode, the LOGOs received over the server port are not processed properly.
This results in stale Fibre Channel IDs at the switch.
Workaround:
Perform
shut
and
no shut
command operations on all the server ports to clear the
stale state on the NPV switch.
CSCsm66194 and CSCsr66209
Symptom
: Logins may not be uniformly balanced across all available border ports when the Cisco
Nexus 5000 Series switch operates in the NPV mode under conditions such as the following:
The switch is reloaded.
NPIV is disabled and re-enabled on the NPV core-switch.
The NPV core-switch is reloaded.
A new NP link is added.
Workaround:
Perform
shut
and
no shut
command
operations on all the server ports to rebalance
the logins.
CSCsu25775
Symptom
: When the Cisco Nexus 5020 Series switch is connected to a 110 V power supply, the
following problems occur:
The syslog displays warnings at bootup. Although the hardware supports the 110 V input, the
operating system incorrectly logs the warning message.
The show environment power command incorrectly displays the available power as a negative
value.
Workaround:
The problem is not significant and the system operates normally with 110 V power
supply input. There is no workaround to avoid the syslog message.
Resolved Caveats—Cisco NX-OS Release 4.0(0)N1(2)
This section lists the resolved caveats for this release.
CSCsq61505
Symptom
: Problems are encountered while upgrading to Cisco NX-OS Release 4.0(0)N1(2) from
Cisco NX-OS Releases 4.0(0)N1(1) or 4.0(0)N1(1a).
Workaround
: None.