HP Integrity rx1620 Internal Cabling Guide for HP Smart Array Controllers - Page 10

Dual Partition Configurations

Page 10 highlights

Cabling for the HP Integrity rx8620 Server Dual Partition Configurations Dual Partition Configurations Figure 1-4 shows the correct cabling for a dual partition configuration, as viewed from the front of the server. Figure 1-4 Smart Array Controller Card with Dual Partition Cabling Port 1/A2 Port 2/A1 Port 1/A2 Port 2/A1 Mass Storage Backplane Connections RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives) To set up the RAID cabling on the top left and top right hot plug hard drives, do the following: Step 1. Verify that the HP Smart Array controller card is installed in PCI slot 8 of the IO Chassis 0. Step 2. Retrieve two cables from the cable kit (A7027-63001). Step 3. Identify the new cables using the colored cable ties which are also contained in the cable kit. For each cable, use two of the same color, one on each end. NOTE One end of each cable has a pull-tab connected to the SCSI connector which is labeled "This Connector to PCI Card". This end of the cable connects to the HP Smart Array card. Step 4. Plug the end of one of the cables with the pull-tab into the SCSI connector Port 1/A2 on the Smart Array card. Repeat for SCSI connector Port 2/A1. Step 5. Route the cables as shown in Figure 1-3 towards the front of the server and over to the Mass Storage Backplane connectors. 6 Chapter 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Cabling for the HP Integrity rx8620 Server
Dual Partition Configurations
Chapter 1
6
Dual Partition Configurations
Figure 1-4 shows the correct cabling for a dual partition configuration, as viewed from the front of the server.
Figure 1-4
Smart Array Controller Card with Dual Partition Cabling
RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives)
To set up the RAID cabling on the top left and top right hot plug hard drives, do the following:
Step 1.
Verify that the HP Smart Array controller card is installed in PCI slot 8 of the IO Chassis 0.
Step 2.
Retrieve two cables from the cable kit (A7027-63001).
Step 3.
Identify the new cables using the colored cable ties which are also contained in the cable kit. For
each cable, use two of the same color, one on each end.
NOTE
One end of each cable has a pull-tab connected to the SCSI connector which is
labeled “This Connector to PCI Card”. This end of the cable connects to the HP Smart
Array card.
Step 4.
Plug the end of one of the cables with the pull-tab into the SCSI connector Port 1/A2 on the Smart
Array card. Repeat for SCSI connector Port 2/A1.
Step 5.
Route the cables as shown in Figure 1-3 towards the front of the server and over to the Mass
Storage Backplane connectors.
Mass Storage Backplane
Connections
Port 1/A2
Port 1/A2
Port 2/A1
Port 2/A1