HP ProLiant 3000 Compaq ProLiant Cluster HA/F100 and HA/F200 Administrator Gui - Page 129
Problem, Possible Cause, Action, Compaq ProLiant, Cluster HA/F200 Poster
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
6-4 Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide Table 6-1 Solving Installation Problems continued Problem Possible Cause Clients do not see the cluster. Clients can only view the virtual servers. Added logical drives are not recognized Windows NT and Redundancy Manager do not support hot-add of logical drives. Redundancy Manager appears to function properly but does not recognize component failover. Cluster may be improperly cabled. Action Clients do not see the cluster itself, only the virtual servers located in the cluster. If you have a virtual server defined, verify that the clients can see the virtual server. Follow the steps below to add logical drives. 1. Uninstall MSCS. 2. Add drives in Disk Administrator. 3. Reinstall MSCS. Refer to the Compaq ProLiant Cluster HA/F200 Poster for proper cabling of the cluster.