Printer power specifications continued

Page 23 highlights

Table 4-5 Printer power specifications (continued) Required electrical circuit (Europe) 230 VAC, 16 A, 50 Hz, single phase, with CEE 7/4 or CEE 7/7 wall receptacle Required power cord Optional auxiliary power for ink system vacuum The printer can use any of the following 4.5 m (14.8 ft) power cords: ● USA: HP part number 8120-6903 ● Europe: HP part number 8120-6899 ● Cord without connector to electric outlet (for use with customer-supplied connector): HP part number 8120-6895 When configured as shipped, if the power cord to the printer is removed, power to the ink system vacuum is removed. If the printer standby power switch is switched off, but the power cord is not removed, power to the vacuum is preserved. The ink system vacuum maintains the negative pressure required for printing operation and prevents ink dripping from the printheads when the printer is idle. You can preserve power to the ink system vacuum during power outages by connecting the supplied power cord (length: 137 cm (4.5 ft)) from the auxiliary power connection (below the ink box racks) to one of the following: ● Wall outlet - 100-240 VAC, 50/60 Hz, provides temporary power to the vacuum system when it is necessary to remove power from the printer for service. ● UPS - customer-supplied uninterruptable power supply, output 100-240 VAC, 50/60 Hz, minimum of 15 watts of power, provides battery backup to the vacuum system in the event of a power failure. UPS is connected to the electric wall outlet. ENWW Power specifications 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Table 4-5
Printer power specifications (continued)
Required electrical circuit (Europe)
230 VAC, 16 A, 50 Hz, single phase, with CEE 7/4 or CEE 7/7 wall receptacle
Required power cord
The printer can use any of the following 4.5 m (14.8 ft) power cords:
USA: HP part number 8120-6903
Europe: HP part number 8120-6899
Cord without connector to electric outlet (for use with customer-supplied
connector): HP part number 8120-6895
Optional auxiliary power for ink system vacuum
When configured as shipped, if the power cord to the printer is removed, power
to the ink system vacuum is removed. If the printer standby power switch is
switched off, but the power cord is not removed, power to the vacuum is
preserved. The ink system vacuum maintains the negative pressure required for
printing operation and prevents ink dripping from the printheads when the
printer is idle.
You can preserve power to the ink system vacuum during power outages by
connecting the supplied power cord (length: 137 cm (4.5 ft)) from the auxiliary
power connection (below the ink box racks) to one of the following:
Wall outlet
100
240 VAC, 50/60 Hz, provides temporary power to the
vacuum system when it is necessary to remove power from the printer for
service.
UPS
customer-supplied uninterruptable power supply, output 100
240
VAC, 50/60 Hz, minimum of 15 watts of power, provides battery backup to
the vacuum system in the event of a power failure. UPS is connected to the
electric wall outlet.
ENWW
Power specifications