HP StorageWorks 2/32 Brocade Access Gateway Administrator's Guide - Supporting - Page 57
AG-1013, Recommended, Action, Severity, Message, Probable, Cause
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
AG-1013 D Recommended Action Severity Verify the configuration of the fabric switch.. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING AG-1013 Message , [AG-1013], ,, INFO, , Failing over all F_Ports mapped to N_Port to other N_Port(s) Probable Cause Recommended Action Severity Indicates that the F_Ports were failed over to another N_Port(s) that is connected to the same fabric. Run the ag --mapshow command to display the updated F-Port to N-Port mapping. INFO AG-1014 Message , [AG-1014], ,, INFO, , Failing back F_Ports to mapped to N_Port Probable Cause Recommended Action Severity Indicates that the N_Port is back online and the F_Ports have been failed back to the N_Ports to which they were mapped. Run the ag --mapshow command to display the updated F-Port to N-Port mapping. INFO Access Gateway Administrator's Guide D-9 Publication Number: 53-1000430-01