HP StorageWorks 2/32 Brocade Fabric Watch Administrator's Guide (53-1000243-01 - Page 107
SFP Class, Default Threshold Values, SFP Class Threshold Defaults
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
Default Threshold Values A SFP Class Table A-11 provides default settings for areas in the SFP class. Note SFPs connected to GbE ports are not monitored. Table A-11 SFP Class Threshold Defaults Area Description Default Threshold Settings Current Monitors SFP current Receive Power Monitors receive power in µWatts Supply Voltage Monitors SFP electrical force in volt(s) Unit: mA Time Base: none Low: 0 High: 50 Buffer: 1 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Unit: mV Time Base: none Low: 3150 High: 3600 Buffer: 10 Temperature Transmit Power Monitors SFP Temperature Monitors transmit power in µWatts Unit: Degrees C Time Base: none Low: -10 High: 85 Buffer: 3 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Default Alarm Settings Changed: 0 Below: 1 Above: 1 In-Between: 0 Threshold State Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 1 Informative Out_of_range Out_of_range Normal Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Normal Fabric Watch Administrator's Guide Publication Number: 53-1000243-01 A-17