HP StorageWorks 4/16 Brocade Fabric OS MIB Reference Guide v6.0.0 (53-1000602- - Page 169
swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1
View all HP StorageWorks 4/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1 5 swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1 The switch port index. Values The physical port number of the switch, plus 1. The valid values for the Brocade 12000, 24000, and 48000 directors are 0 through maximum number of ports. swFCPortType 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.2 The type of ASIC for the switch port. Values Possible values are: • stitch (1) • flannel (2) • loom (3) (Brocade 2000 series) • bloom (4) (Valid value for Brocade 3250, 3850, 3900, 12000, 24000) • rdbloom (5) • wormhole (6) • other (7) (Valid value for Brocade 200E, 4012, 4100, 4900, 7500, 7600, and 48000) • unknown (8) swFCPortPhyState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3 The physical state of the port. Values Possible values are: • noCard (1) No card is present in this switch slot. • noTransceiver (2) No Transceiver module in this port (Transceiver is the generic name for GBIC, SFP, and so on). • laserFault (3) The module is signaling a laser fault (defective GBIC). • noLight (4) The module is not receiving light. • noSync (5) The module is receiving light but is out of sync. • inSync (6) The module is receiving light and is in sync. • portFault (7) The port is marked faulty (defective GBIC, cable, or device). • diagFault (8) The port failed diagnostics (defective G_Port or FL_Port card or motherboard). • lockRef (9) Port is locking to the reference signal. Fabric OS MIB Reference 151 53-1000602-01