HP StorageWorks 4/32 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 424
NBFS-1003, Database Acknowledge Wait
View all HP StorageWorks 4/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 424 highlights
59 NBFS-1003 Severity ERROR NBFS-1003 Message , [NBFS-1003], ,, WARNING, , DB_XMIT_SET flag not set in state , input , port Probable Cause Indicates the database transmit set flag was not set for the specified input state on the specified port. Neighbor finite state machine (NBFSM) states are as follows: • 0 - Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full Recommended No action is required. The Fabric OS automatically recovers from this problem. Action Severity WARNING 366 Fabric OS Message Reference 53-1001157-01
366
Fabric OS Message Reference
53-1001157-01
NBFS-1003
59
Severity
ERROR
NBFS-1003
Message
<timestamp>, [NBFS-1003], <sequence-number>,, WARNING, <system-name>, DB_XMIT_SET
flag not set in state <current state name>, input <state name>, port <portnumber>
Probable Cause
Indicates the database transmit set flag was not set for the specified input state on the specified
port. Neighbor finite state machine (NBFSM) states are as follows:
•
0 - Down
•
1 - Init
•
2 - Database Exchange
•
3 - Database Acknowledge Wait
•
4 - Database Wait
•
5 - Full
Recommended
Action
No action is required. The Fabric OS automatically recovers from this problem.
Severity
WARNING