HP StorageWorks 4/32 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 89
AG-1023
View all HP StorageWorks 4/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
AG-1023 2 Probable Cause Indicates the specified F_Port is failing over to its preferred N_Port. Recommended Run ag --mapshow to display the updated F_Port-to-N_Port mapping. Action Severity INFO AG-1023 Message , [AG-1023], ,, INFO, , F_Port mapped to offline N_Port is failed over to its preferred N_Port . Probable Cause Indicates the specified N_Port has failed to come online. The F_Port mapped to this N_Port had its preferred set and is online. Recommended Run the ag --mapshow command to display updated F_Port -to -N_Port mapping. Action Severity INFO AG-1024 Message , [AG-1024], ,, INFO, , F_Port is failed back to its preferred N_Port . Probable Cause Indicates the specified N_Port is failing back F_Ports, which are failed over to some other N_Port. Recommended Run the ag --mapShow command to display the updated F_Port-to-N_Port mapping. Action Severity INFO AG-1025 Message , [AG-1025], ,, ERROR, , Port group of Slave N_Port is different than its Master N_Port . Probable Cause Indicates that the port groups of the Master and Slave N_Ports are different while the Trunk Area assigned to the attached F_Ports on the edge switch is the same. Recommended Run the porttrunkarea --show command on the attached switch to display that the Trunk Area is Action assigned to all ports in the system and run porttrunkarea --enable to reconfigure the Trunk Area. Severity ERROR AG-1026 Message , [AG-1026], ,, WARNING, , Unable to handle the login request on port due to insufficient resources. Fabric OS Message Reference 31 53-1001157-01