Additional Fabric OS 6.1.x enhancements Additional Fabric OS 6.1.x enhancements include: • Provides new Fabric OS commands to rename an alias, a zone, and a zone configuration: • Zone -copy-Copies the zone object to a new zone object. • Zoneobjectrename-Renames the zone object. • Detects and handles a corrupted zone configuration [under /etc/fabos/zone*] gracefully instead of rebooting. The switch also logs the error in RASLog. • Adds a new command that provides both the WWN (World Wide Name) and serial number of the switch. Added an -sn option to display the serial number. For example, wwn -sn returns both the WWN and serial number data • Provides additional information on a faulty port in Fabric Watch to aid in troubleshooting. • Enables use of passive FTP to download firmware. • Enables the user to specify a quality password policy that prevents the selection of passwords with consecutive, identical characters. • Uses multiple NTP servers with the tsclockserver command for redundancy. For example, if one site NTP server fails (DR scenario) there is a backup that can be reached by the switches. • Logs a RASLog message when a 2.x switch joins the fabric. • HA failover and user notification occurs on the 4/256 SAN Director when there is a failed Ethernet chip (Oscillator chip). Fabric OS 6.1.0 fixes Table 6 lists defects closed in the Fabric OS 6.1.0 firmware release. Table 6 Fabric OS 6.1.0 closed defects Closed defect summary Solution Autonegotiation with specific HBAs does not bring the ports to the correct maximum speed. Fixed in Fabric OS 6.1.0 An FC Analyzer trace shows an FCR port is receiving periodic RRQ and ABTS frames. Fixed in Fabric OS 6.1.0 HAReboot on MP Router 400 (with the edge fabric is an EOS fabric) results in port bouncing due to no BB credits. Fixed in Fabric OS 6.1.0 After switchdisable and switchenable all FCR switches, from the edge fabric translate domain are missing Fixed in Fabric OS 6.1.0 Unable to access CUP Port on local or cascaded switch through DC Director. Fixed in Fabric OS 6.1.0 In some rare scenarios, application hangs are noticed on the Server when FCFW related actions are taken on the fabric. Fixed in Fabric OS 6.1.0 Management server daemon (msd) panic on switch during fabric bring up. Fixed in Fabric OS 6.1.0 In a FICON configuration, VE port persists in offline state after link down when GbE link is routed through a network switch Fixed in Fabric OS 6.1.0 Unable to establish connectivity between HBA and Storage. Fixed in Fabric OS 6.1.0 CP failover on a 4/256 SAN Director. Fixed in Fabric OS 6.1.0 FCFW devices: I/O fails on the backbone fabric. Fixed in Fabric OS 6.1.0 LD ISL sometimes comes up in VC_RDY mode, not QoS mode. Fixed in Fabric OS 6.1.0 HP StorageWorks Fabric OS 6.1.0a release notes 13