HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.0a release notes (5697-7679 - Page 15
HP StorageWorks Fabric OS 6.1.0a release notes
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Closed defect summary Solution When a switch's IDID mode is currently OFF and we disable the switch, the rest of the switches in the fabric get a premature duplicate Fixed in Fabric OS 6.1.0 message. Async error reporting events are lost if detected immediately after switch boot. Fixed in Fabric OS 6.1.0 Fabric Manager: Configdownload actually downloads all the disruptive parameters in the Validation step in Fabric Manager, when Fixed in Fabric OS 6.1.0 the switch is in a disabled state. If a device tries to login to an NPIV port using a port WWN, which is already used by another device that has already logged in, the switch Fixed in Fabric OS 6.1.0 simply drops the new login (FDISC) request instead of rejecting it. Incorrect FRU Update date is received for Brocade_Chassis class. Fixed in Fabric OS 6.1.0 SetInstance call is failing for Brocade_Switch class. Fixed in Fabric OS 6.1.0 Problem attempting to lock a port as an L_Port and configure the duplex mode using the CLI. Fixed in Fabric OS 6.1.0 Inconsistent support for switch service tag between CLI and Web Tools. Fixed in Fabric OS 6.1.0 Port_scn removes logical paths from wrong port. Fixed in Fabric OS 6.1.0 IOCTL not allowed: cmd 0x40040911, pid 11347 (ficonshow) message seen on the console. Fixed in Fabric OS 6.1.0 Validation of IP address to SetProperty/SetInstance for CommunityInfoSet on Brocade_Switch class is not present on higher version (5.3,6.0). Fixed in Fabric OS 6.1.0 nsd killed during overnight iSCSI blade slotpoweroff/on testing. Fixed in Fabric OS 6.1.0 bladebeacon command should fail for core blades and switchshow command should not show beacon status for core blades in the DC Director chassis. Fixed in Fabric OS 6.1.0 Even after deleting enabled DDset the DD members of that particular ddset are still shown as enabled. Fixed in Fabric OS 6.1.0 frureplace wwn command for DC Director platform takes over ten minutes to complete. Fixed in Fabric OS 6.1.0 Web Tools - USB admin always displays firmware build size incorrectly as 32768 bytes whereas CLI shows the actual size. Fixed in Fabric OS 6.1.0 CRC errors mismatch between porterrshow and portstatsshow output. Fixed in Fabric OS 6.1.0 Upon repeated reboots of the MP Router switch, ExternalInput Oops message seen on the console, (stress-to-fail test). Fixed in Fabric OS 6.1.0 FCIP testing with tape pipelining enabled results in failures. Fixed in Fabric OS 6.1.0 Shortly after cfgdisable on an edge 4/256 SAN Director, got a raslogd core dump. Fixed in Fabric OS 6.1.0 Changing desired distance by issuing "portcfglongdistance ,slot/port> 1d 1 " from lower WWN switch often Fixed in Fabric OS 6.1.0 causes E_Port to stuck at Unknown or send ECP failed and disabled. With EX ports configured observed VERIFY on performing hafailover - Failed expression: 0, c2_debug.c, line = 7896 Call back trace:Trace: bfe4241c when EX_Ports exist. Fixed in Fabric OS 6.1.0 HP StorageWorks Fabric OS 6.1.0a release notes 15