HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.0a release notes (5697-7679 - Page 17

Fabric OS 6.1.0a

Page 17 highlights

Closed defect summary IFCCs caused by incorrect positioning for FICON Read Tape Pipelining. Management server GMAL command is being rejected with reason 5, Logical Busy. FCIP Compression enhanced to take advantage of higher compression rates. Solution Fixed in Fabric OS 6.1.0 Fixed in Fabric OS 6.1.0 Fixed in Fabric OS 6.1.0 Fabric OS 6.1.0a fixes Table 7 lists defects closed in this Fabric OS 6.1.0a firmware release. Table 7 Fabric OS 6.1.0a closed defects Closed defect summary Solution Under rare conditions, fabric mode TopTalker monitor does not display correct flow values. Fixed in Fabric OS 6.1.0a Attempting to configure port mirroring on a director with both 4Gb and 8Gb blades may result in a software Verify error. Fixed in Fabric OS 6.1.0a After repeatedly running bladedisable/enable on one FC8-48 blade for six hours, a DC Director panics. Fixed in Fabric OS 6.1.0a FCR matrix settings may not persist after hafailover on a 4/256 SAN Director. Fixed in Fabric OS 6.1.0a When disabling/enabling a port, Port Fencing disables the port because the allowable number of invalid transmission words is exceeded. Fixed in Fabric OS 6.1.0a Under rare conditions, a DC Director panics during SAK IRNDUP when the software watchdog detects an unexpected termination of the FICON CUP daemon (ficud). Fixed in Fabric OS 6.1.0a Port Based Routing with DLS ON does not immediately balance the load when adding an ISL. Fixed in Fabric OS 6.1.0a Ex_Port fails to come online after downgrading firmware from Fabric OS 6.x to 5.3 under certain conditions. Fixed in Fabric OS 6.1.0a Fastwrite performance issue with a particular FCIP ex-port configuration. Fixed in Fabric OS 6.1.0a During storage failover/failback test with IP over FC, traffic stops and fails to recover in single and dual backbone configurations. Fixed in Fabric OS 6.1.0a HP StorageWorks Fabric OS 6.1.0a release notes 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

Closed defect summary
Solution
IFCCs caused by incorrect positioning for FICON Read Tape
Pipelining.
Fixed in Fabric OS 6.1.0
Management server GMAL command is being rejected with reason
5,
Logical Busy
.
Fixed in Fabric OS 6.1.0
FCIP Compression enhanced to take advantage of higher
compression rates.
Fixed in Fabric OS 6.1.0
Fabric OS 6.1.0a
xes
Table 7
lists defects closed in this Fabric OS 6.1.0a
rmware release.
Table 7 Fabric OS 6.1.0a closed defects
Closed defect summary
Solution
Under rare conditions, fabric mode TopTalker monitor does not
display correct
ow values.
Fixed in Fabric OS 6.1.0a
Attempting to con
gure port mirroring on a director with both 4Gb
and 8Gb blades may result in a software
Verify
error.
Fixed in Fabric OS 6.1.0a
After repeatedly running
bladedisable
/
enable
on one FC8-48
blade for six hours, a DC Director panics.
Fixed in Fabric OS 6.1.0a
FCR matrix settings may not persist after
hafailover
on a 4/256
SAN Director.
Fixed in Fabric OS 6.1.0a
When disabling/enabling a port, Port Fencing disables the port
because the allowable number of invalid transmission words is
exceeded.
Fixed in Fabric OS 6.1.0a
Under rare conditions, a DC Director panics during SAK IRNDUP
when the software watchdog detects an unexpected termination of
the FICON CUP daemon (
ficud
).
Fixed in Fabric OS 6.1.0a
Port Based Routing with DLS ON does not immediately balance the
load when adding an ISL.
Fixed in Fabric OS 6.1.0a
Ex_Port fails to come online after downgrading
rmware from Fabric
OS 6.x to 5.3 under certain conditions.
Fixed in Fabric OS 6.1.0a
Fastwrite performance issue with a particular FCIP ex-port
con
guration.
Fixed in Fabric OS 6.1.0a
During storage failover/failback test with IP over FC, traf
c stops and
fails to recover in single and dual backbone con
gurations.
Fixed in Fabric OS 6.1.0a
HP StorageWorks Fabric OS 6.1.0a release notes
17