Closed defect summary Solution When a switch's IDID mode is currently OFF and we disable the switch, the rest of the switches in the fabric get a premature duplicate Fixed in Fabric OS 6.1.0 message. Async error reporting events are lost if detected immediately after switch boot. Fixed in Fabric OS 6.1.0 Fabric Manager: Configdownload actually downloads all the disruptive parameters in the Validation step in Fabric Manager, when Fixed in Fabric OS 6.1.0 the switch is in a disabled state. If a device tries to login to an NPIV port using a port WWN, which is already used by another device that has already logged in, the switch Fixed in Fabric OS 6.1.0 simply drops the new login (FDISC) request instead of rejecting it. Incorrect FRU Update date is received for Brocade_Chassis class. Fixed in Fabric OS 6.1.0 SetInstance call is failing for Brocade_Switch class. Fixed in Fabric OS 6.1.0 Problem attempting to lock a port as an L_Port and configure the duplex mode using the CLI. Fixed in Fabric OS 6.1.0 Inconsistent support for switch service tag between CLI and Web Tools. Fixed in Fabric OS 6.1.0 Port_scn removes logical paths from wrong port. Fixed in Fabric OS 6.1.0 IOCTL not allowed: cmd 0x40040911, pid 11347 (ficonshow) message seen on the console. Fixed in Fabric OS 6.1.0 Validation of IP address to SetProperty/SetInstance for CommunityInfoSet on Brocade_Switch class is not present on higher version (5.3,6.0). Fixed in Fabric OS 6.1.0 nsd killed during overnight iSCSI blade slotpoweroff/on testing. Fixed in Fabric OS 6.1.0 bladebeacon command should fail for core blades and switchshow command should not show beacon status for core blades in the DC Director chassis. Fixed in Fabric OS 6.1.0 Even after deleting enabled DDset the DD members of that particular ddset are still shown as enabled. Fixed in Fabric OS 6.1.0 frureplace wwn command for DC Director platform takes over ten minutes to complete. Fixed in Fabric OS 6.1.0 Web Tools - USB admin always displays firmware build size incorrectly as 32768 bytes whereas CLI shows the actual size. Fixed in Fabric OS 6.1.0 CRC errors mismatch between porterrshow and portstatsshow output. Fixed in Fabric OS 6.1.0 Upon repeated reboots of the MP Router switch, ExternalInput Oops message seen on the console, (stress-to-fail test). Fixed in Fabric OS 6.1.0 FCIP testing with tape pipelining enabled results in failures. Fixed in Fabric OS 6.1.0 Shortly after cfgdisable on an edge 4/256 SAN Director, got a raslogd core dump. Fixed in Fabric OS 6.1.0 Changing desired distance by issuing "portcfglongdistance ,slot/port> 1d 1 " from lower WWN switch often Fixed in Fabric OS 6.1.0 causes E_Port to stuck at Unknown or send ECP failed and disabled. With EX ports configured observed VERIFY on performing hafailover - Failed expression: 0, c2_debug.c, line = 7896 Call back trace:Trace: bfe4241c when EX_Ports exist. Fixed in Fabric OS 6.1.0 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

Closed defect summary
Solution
When a switch’s IDID mode is currently OFF and we disable the
switch, the rest of the switches in the fabric get a premature duplicate
message.
Fixed in Fabric OS 6.1.0
Async error reporting events are lost if detected immediately after
switch boot.
Fixed in Fabric OS 6.1.0
Fabric Manager:
Configdownload
actually downloads all the
disruptive parameters in the Validation step in Fabric Manager, when
the switch is in a disabled state.
Fixed in Fabric OS 6.1.0
If a device tries to login to an NPIV port using a port WWN, which is
already used by another device that has already logged in, the switch
simply drops the new login (FDISC) request instead of rejecting it.
Fixed in Fabric OS 6.1.0
Incorrect FRU Update date is received for Brocade_Chassis class.
Fixed in Fabric OS 6.1.0
SetInstance
call is failing for Brocade_Switch class.
Fixed in Fabric OS 6.1.0
Problem attempting to lock a port as an L_Port and con
gure the
duplex mode using the CLI.
Fixed in Fabric OS 6.1.0
Inconsistent support for switch service tag between CLI and Web
Tools.
Fixed in Fabric OS 6.1.0
Port_scn
removes logical paths from wrong port.
Fixed in Fabric OS 6.1.0
IOCTL not allowed: cmd 0x40040911, pid 11347 (
ficonshow
)
message seen on the console.
Fixed in Fabric OS 6.1.0
Validation of IP address to SetProperty/SetInstance for
CommunityInfoSet on Brocade_Switch class is not present on higher
version (5.3,6.0).
Fixed in Fabric OS 6.1.0
nsd
killed during overnight iSCSI blade
slotpoweroff
/
on
testing.
Fixed in Fabric OS 6.1.0
bladebeacon
command should fail for core blades and
switchshow
command should not show beacon status for core
blades in the DC Director chassis.
Fixed in Fabric OS 6.1.0
Even after deleting enabled DDset the DD members of that particular
ddset are still shown as enabled.
Fixed in Fabric OS 6.1.0
frureplace wwn
command for DC Director platform takes over
ten minutes to complete.
Fixed in Fabric OS 6.1.0
Web Tools - USB admin always displays
rmware build size
incorrectly as 32768 bytes whereas CLI shows the actual size.
Fixed in Fabric OS 6.1.0
CRC errors mismatch between
porterrshow
and
portstatsshow
output.
Fixed in Fabric OS 6.1.0
Upon repeated reboots of the MP Router switch,
ExternalInput
Oops
message seen on the console, (stress-to-fail test).
Fixed in Fabric OS 6.1.0
FCIP testing with tape pipelining enabled results in failures.
Fixed in Fabric OS 6.1.0
Shortly after
cfgdisable
on an edge 4/256 SAN Director, got a
raslogd core dump.
Fixed in Fabric OS 6.1.0
Changing desired distance by issuing "
portcfglongdistance
,
slot
/
port
>
1d 1
<
distance
>” from lower WWN switch often
causes E_Port to stuck at Unknown or send ECP failed and disabled.
Fixed in Fabric OS 6.1.0
With EX ports con
gured observed VERIFY on performing
hafailover
- Failed expression: 0, c2_debug.c, line = 7896
Call back trace:Trace: bfe4241c <asic_valid_data+0x624/0x7a4
[condor2_module]> when EX_Ports exist.
Fixed in Fabric OS 6.1.0
16