HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 21
HP StorageWorks Fabric OS 6.1.1d release notes, Solution, Closed defect summary
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Closed defect summary Solution Internal server ports on an embedded platform; traffic may stop due Fixed in Fabric OS 6.1.1. to loss of buffer credit. Mixed fabric of McDATA and Brocade switches cannot be managed Fixed in Fabric OS 6.1.1. if only IPv6 addressing is supported. HBA is not following Fibre Channel protocol standards, which could Fixed in Fabric OS 6.1.1. cause a switch reboot. Problems in an IP network could cause a switch running Fabric OS 5.3.x to panic. Fixed in Fabric OS 6.1.1. Device with slow initialization sequence may cause the switch to mis- Fixed in Fabric OS 6.1.1. takenly establish virtual channels on an F_Port. Web tools zoning breaks when third party storage virtualization appli- Fixed in Fabric OS 6.1.1. ance is changed to standby mode leading to Web Tools hangs. FICON tape write pipelining selectively resets after CmdRetry to NoOp sequence to LBY, causing tape job failures. Fixed in Fabric OS 6.1.1. F_Port link initialization failure exposed by new third-party device be- Fixed in Fabric OS 6.1.1. havior, where switch continues to send idles after NOS from HBA. SupportSave command using DCFM does not contain information Fixed in Fabric OS 6.1.1. from the standby CP. HP 400 Multi-Protocol Router sends the wrong sense code during tape Fixed in Fabric OS 6.1.1. backup with pipelining enabled. Web Tools: DCX blade attention LEDs on the switch view GUI window Fixed in Fabric OS6.1.1. do not turn amber when the blade needs attention. FICON PTP VTS selective resets and aborted sequences are caused by incorrect entry into FICON tape read pipelining. Fixed in Fabric OS 6.1.1. After renaming a port group name to blank from Web Tools, the port Fixed in Fabric OS 6.1.1. group is deleted. If EE monitors are restored from flash on a switch that has TopTalker monitors, there is no warning or error when the TopTalker monitor installation recovery fails. Fixed in Fabric OS 6.1.1. The aaaconfig command online help text needs to be corrected to Fixed in Fabric OS 6.1.1. clearly indicate LDAP cannot be configured while FIPS is enabled. FR-18i faulted after overnight stress testing. Fixed in Fabric OS 6.1.1. A TI zone with an invalid (too high) port number can cause a kernel Fixed in Fabric OS 6.1.1. panic. ARRd Daemon had multiple restarts that ultimately let to a KSWD event. Fixed in Fabric OS 6.1.1. Fast Write can obtain incorrect FCP command data length if the op- Fixed in Fabric OS 6.1.1. tional additional CDB length is selected. Hardware LED shows error status (flashing amber or green), even though all FRUs are okay. Fixed in Fabric OS 6.1.1. HP StorageWorks Fabric OS 6.1.1d release notes 21