HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.1d release notes (5697-7962 - Page 24
Fabric OS 6.1.1d fixes
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Closed defect summary Solution Panic occurs with switch in Access Gateway Mode when N-Port to F- Fixed in Fabric OS 6.1.1c. Port trunking is enabled. Unexpected return code from Fast Write and Tape Pipelining Fixed in Fabric OS 6.1.1c. causes GE port traffic interrupt. When first upgrading a newly installed FOS v6.0.x director to FOS v6.1.x, there is a very small window that 8G-blades may fault. Fixed in Fabric OS 6.1.1c. Fabric OS 6.1.1d fixes Table 13 lists defects closed in the Fabric 6.1.1d firmware release. Table 13 Fabric OS 6.1.1d closed defects Closed defect summary After multiple controller reboots, PLOGI Accept is dropped due to missing CAM entry. Solution Fixed in Fabric OS 6.1.1d. Workaround: Prior to upgrade to 6.1.1d, do Portdisable/portenable on device port to re-gain host/device connection. VI to PT routes are deleted following portdisable/enable on HP Stor- Fixed in Fabric OS 6.1.1d. ageWorks SAN Director 48 Port FC blade. Switch may experience timeouts and traffic interruption during HCL operation of neighboring switch with FOS v6.2.0. Fixed in Fabric OS 6.1.1d. Observed kernel panic on HP StorageWorks DC SAN Director, in RTE Fixed in Fabric OS 6.1.1d. module. During HA recovery, Fabric Watch failed to initialize on fully populated Fixed in Fabric OS 6.1.1d. Brocade DCX. Reports switch health status as Marginal/Down. Traffic is not impacted, but DCFM call home will not be initiated. License database can be corrupted after configdonwload and can not Fixed in Fabric OS 6.1.1d. be added back. 4G platform can disable QoS but cannot enable QoS without license. Customer may experience high CPU load and unexpected blade errors Fixed in Fabric OS 6.1.1d. due to issue responding to ASIC generated interrupts. Some OS/HBA combinations take down FC link when N_port generated RSCNs are delivered by switch with 0x08 (FOS 6.1.1b & 6.1.0g) or 0x20 (6.1.0x) as event qualifier. Fix reverts back to FOS v6.0 value of 0x00. Fixed in Fabric OS 6.1.1d. Webtools GUI freezes a few seconds about every 15 seconds. Webtools light stops blinking, and cannot scroll any windows. Fixed in Fabric OS 6.1.1d. 24