HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0d release notes (5697-0353 - Page 34
FICON PTP VTS Selective Resets and Aborted sequences caused
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
N-Port between AG and Edge Switch (300) may become stuck at E_Port Unknown state.D Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Disable and then enable the port on the AG to bring the port back online as an N-Port. After multiple successive fastboots of an HP StorageWorks DC04 SAN Director, there was a panic due to the zone daemon dying. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Fastboot a single time. FICON PTP VTS Selective Resets and Aborted sequences caused by incorrect entry into FICON tape read pipelining. Fixed in Fabric OS 6.2.0. EX_Port fails to come online after downgrading firmware from Fabric OS 6.x to 5.3 under certain conditions. Fixed in Fabric OS 6.2.0. Tstimezone settings cannot be changed or restored with configdownload. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Remove the ts.tz parameter in the config file and then download. If a large number of EX_Ports are enabled at the same time, occasionally some fail due to incompatible flow control parameters. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Portdisable and then enable the EX_Ports that failed. In some instances, portshow may display inaccurate port authentication description or state after a CP failover. Fixed in Fabric OS 6.2.0. Internal server ports on embedded platform: traffic may stop due to loss of buffer credit. Fixed in Fabric OS 6.2.0. The error message is cryptic when the interop fabric contains more than 60 devices in the default zone and the user tries cfgenablecfg- Fixed in Fabric OS 6.2.0. disable. When disabling/enabling a port, port fencing disables the port because the allowable number of invalid transmission words is exceeded. Fixed in Fabric OS 6.2.0. Ag --show on an HP StorageWorks 8/8 or 8/24 SAN Switch shows incorrect edge switch IP address after a slave port is swapped with an N-port outside of the trunk group. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Reboot the switch and ag --show cli will show the correct output. The 32-character switchname and chassisname extensions do not fully display in RASLog outputs, such as errdump or supportsave output. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Use only 16-character switchname and chassisname fields if full name display in the logs is required. FFDC occurs when 16-31 char switch/chassis name is input on a platform that only supports up to 15. Fixed in Fabric OS 6.2.0. I2C response failure and subsequent reset occasionally results in HP StorageWorks DC SAN Backbone Director fan fault errors. Fixed in Fabric OS 6.2.0. 34