HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0d release notes (5697-0353 - Page 41
After configuring HP StorageWorks 8/8 or 8/24 SAN Switch AG so
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
Conversion of uwatt to dbm for GE ports Tx Rx values shown in Web Tools are incorrect. Fixed in Fabric OS 6.2.0. HP StorageWorks 8/40 SAN Switch: FRU faulty status is not recovered correctly. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Turn on the power switch as soon as possible after inserting a fan/power supply unit into the system. Third-party array responds to ADISC with LOGO only over router fabric, S_ID does not match N_ID. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: For McDATA mode edge fabric, only McDATA switches have to be connected directly to FCR. The work around is valid as long as we have only McDATA switches directly connected to Ex-Ports. Ipfilter - Audit log (SEC- 3035, 3036, 3037): message properties generating log without the appropriate key word. Fixed in Fabric OS 6.2.0. AG trunks are not formed correctly when connected to an embedded switch. Fixed in Fabric OS 6.2.0. Tape Selective Reset error due to incorrect handling of Early End Synchronization status. Fixed in Fabric OS 6.2.0. F_Port prefers to multiple N_Ports Fixed in Fabric OS 6.2.0. FICON Device Level Ack Emulation Processing error. Fixed in Fabric OS 6.2.0. Command ipaddrshow does not show the IP address of a blade that is seated in slot 12 of an HP StorageWorks DC SAN Backbone Director. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Issue ipaddrshow -slot 12 to get the information. Re-key of LUNs hosted through active/passive ports will not complete if started on the passive path. Fixed in Fabric OS 6.2.0. Wave Length column in port optics dialog is currently blank. Fixed in Fabric OS 6.2.0. Host may lose targets on edge AG in cascaded setup when failover from core-AG to another core-AG connected to different edge fabric switches. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Disable/enable the N_Port. Web Tools zoning breaks when third-party storage virtualization appliance changed to standby mode. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Change the third-party storage virtualization appliance to standby cf mode. The removal of an encryption performance upgrade license is not prevented. Fixed in Fabric OS 6.2.0. After configuring HP StorageWorks 8/8 or 8/24 SAN Switch AG so that F_Port Trunking works and then performing portdisable on NPorts and then hareboot the 8/8 or 8/24 SAN Switch AG caused unexpected termination of AGD Fixed in Fabric OS 6.2.0. HP StorageWorks Fabric OS 6.2.0d release notes 41