HP StoreOnce 4430 HP StoreOnce Backup System Concepts and Configuration Guidel - Page 52

Scenario 1, single fabric with dual switches, recommended, Zoning by WWPN

Page 52 highlights

Scenario 1, single fabric with dual switches, recommended Figure 40 illustrates the logical connectivity between the hosts and the VTLs and their FC ports. The arrows illustrate accessibility, not data flow. FC configuration • Multiple switches within a single fabric • All hosts can see the robots over two separate switches • Zoning by WWPN • Each zone to include a host and the required targets on the HP B6200 Backup System • Equivalent ports from each node can see the same switch B6200 VTL configuration • Default library configuration is 50% drives presented to Port 1, 50% presented to Port 2 • Up to 120 WWNs can be presented to Port 1 and Port 2 • On B6200 failover all WWNs of failed node are automatically transferred to the corresponding port on the other node. This is transparent to the hosts. Figure 26 VTLs presented to two ports and into dual switches in a single Fabric, recommended configuration 52 Configuring FC to support failover in a StoreOnce B6200 Backup system environment

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122

Scenario 1, single fabric with dual switches, recommended
Figure 40 illustrates the logical connectivity between the hosts and the VTLs and their FC ports. The
arrows illustrate accessibility, not data flow.
FC configuration
Multiple switches within a single fabric
All hosts can see the robots over two separate switches
Zoning by WWPN
Each zone to include a host and the required targets on the HP B6200 Backup System
Equivalent ports from each node can see the same switch
B6200 VTL configuration
Default library configuration is 50% drives presented to Port 1, 50% presented to Port 2
Up to 120 WWNs can be presented to Port 1 and Port 2
On B6200 failover all WWNs of failed node are automatically transferred to the corresponding
port on the other node. This is transparent to the hosts.
Figure 26 VTLs presented to two ports and into dual switches in a single Fabric, recommended
configuration
52
Configuring FC to support failover in a StoreOnce B6200 Backup system environment