HP StoreOnce 4430 HP StoreOnce Backup System Concepts and Configuration Guidel - Page 53
Scenario 2, single fabric with dual switches, not advised, FC configuration, B6200 VTL configuration
View all HP StoreOnce 4430 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
If FC switch1 fails, Host A and Host B lose access to their backup devices. Hosts C and D still have access to the media changers and to 50% of the drives on VTL2 and 50% of the drives on VTL1 B6200 failover between nodes is enabled. Scenario 2, single fabric with dual switches, not advised The FC configuration is the same in this scenario, but the VTLs are presented to a single port. This configuration is not advised because it compromises the B6200 autonomic failover facility. FC configuration • Multiple switches within a single fabric • All hosts can see the robots over two separate switches • Zoning by WWPN • Each zone to include a host and the required targets on the HP B6200 Backup system • Equivalent ports on each node see different switches B6200 VTL configuration • B6200 failover nodes will not failover if we lose a FC port on the node • Up to 120 WWNs can be presented to the individual port • Loss of a port or switch means that all access is lost to the VTLs that are dedicated to that port • Library configuration is all drives presented entirely to a single port, either Port 1 or Port 2 Figure 27 Separate VTLs presented to separate ports and into different switches in different Fabrics, not recommended Scenario 2, single fabric with dual switches, not advised 53