Husqvarna AUTOMOWER 220 AC Owners Manual - Page 29
while result in a broken circuit., Laying the boundary wire in towards the charging
View all Husqvarna AUTOMOWER 220 AC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
3. INSTALLATION The boundary wire must not be crossed on the path to and from an island. Laying the boundary wire in towards the charging station The boundary wire can be routed in several different 1. ways in towards the charging station. The best alternative is to route the wire completely outside the charging station, see alternative 1. The wire can also be placed under the charging station plate as shown 2. in alternative 2 in the illustration. However, the wire should not be placed outside alternative 2 because it can then be difficult for Automower to find the charging station. When connecting to the charging station, the right end of the boundary wire should be guided into the right-hand hole and the cable's left end in the left-hand hole. Joining the boundary wire If the boundary wire is not long enough and needs to be spliced: Use original solderless coupler. It is waterproof and gives a reliable electrical connection. To splice: Insert both cable ends in the coupler. Now press down the button on top of the connector fully. Use a pair of pliers or the like, as the button on the connector is difficult to press down by hand. IMPORTANT INFORMATION Twisted cables, or a screw terminal (chock-block), insulated with insulation tape is not a satisfactory splice. Soil moisture will cause the conductors to oxidize and after a while result in a broken circuit. 30 - English 3012-686US 3012-671 3012-462 3012-832