Maintenance Restoring from service position 1 Grip the front edge of the unit and loosen the lock, fold down and slide in the unit. 2 Replace the cutting height stay and the belt. Removing the BioClip plug To change a Combi unit from BioClip function to cutting unit with rear ejection, remove the BioClip plug located under the unit with three screws. 1 Put the unit in the service position, see Placing in the service position. 2 Remove the three screws holding the BioClip plug, and remove the plug. 3 Tension the belt with the belt adjuster. 4 Fit the front cover. Checking the blades To achieve the best mowing results it is important that the blades are undamaged and well-sharpened. Check that the blades' attachment screws are tight. 3 Tip: Fit three full-thread screws M8x15 mm in the screw holes to protect the threads. 4 Replace the unit in normal position. Fit the BioClip plug in the reverse order. IMPORTANT INFORMATION Replacing or sharpening the blades should be conducted by an authorised service workshop. The blades should be balanced after sharpening. Damaged blades should be replaced when hitting obstacles that result in a breakdown. Let the service centre assess whether the blade can be sharpened or must be replaced. English - 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

English
– 31
Maintenance
Restoring from service position
1
Grip the front edge of the unit and loosen the lock, fold
down and slide in the unit.
2
Replace the cutting height stay and the belt.
3
Tension the belt with the belt adjuster.
4
Fit the front cover.
Checking the blades
To achieve the best mowing results it is important that the
blades are undamaged and well-sharpened.
Check that the blades’ attachment screws are tight.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles
that result in a breakdown. Let the service centre assess
whether the blade can be sharpened or must be replaced.
Removing the BioClip plug
To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.
1
Put the unit in the service position, see Placing in the
service position.
2
Remove the three screws holding the BioClip plug, and
remove the plug.
3
Tip: Fit three full-thread screws M8x15 mm in the screw
holes to protect the threads.
4
Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
IMPORTANT INFORMATION
Replacing or sharpening the
blades should be conducted by an authorised service
workshop.