Husqvarna Z146 Owner Manual - Page 23

Battery

Page 23 highlights

MAINTENANCE IMPORTANT INFORMATION Do not open or remove battery caps or covers. Adding or checking level of electrolyte is not necessary. Always use two wrenches for the terminal screws. CAUTION! Lead-acid batteries generate explosive gases. Keep sparks, flame and smoking materials away from batteries. Always wear eye protection when around batteries. Battery If the battery is too weak to start the engine, it must be recharged. Jumper Cable Use 1. Connect each end of the RED cable to the POSITIVE (+) terminal on each battery, taking care not to short against chassis. 2. Connect one end of the BLACK cable to the NEGATIVE (-) terminal of the fully charged battery. 3. Connect the other end of the BLACK cable to a good CHASSIS GROUND on the mower with the discharged battery, away from the fuel tank and battery. STD BATTERY STATE OF CHARGE APPROXIMATE CHARGING TIME* TO FULL CHARGE AT 80O F Maximum Rate at: 50 Amps 30 Amps 20 Amps 10 Amps 12.6V 100% - FULL CHARGE - 12.4V 75% 20 min. 35 min. 48 min. 90 min. 12.2V 50% 45 min. 75 min. 95 min. 180 min. 12.0V 25% 65 min. 115 min. 145 min. 280 min. 11.8V 0% 85 min. 150 min. 195 min. 370 min. *Charging time depends on battery capacity, condition, age, temperature and efficiency of charger Cleaning battery and terminals Corrosion and dirt on the battery and terminals can cause the battery to lose power. 1. Loosen the two nuts attached to the side J bolts just enough that the battery mount bracket slides down off the battery. To remove cables, reverse order 1. Remove BLACK cable first from chassis and then from the fully charged battery. 2. Remove RED cable last from both batteries. The mower is equipped with a maintenance free battery and does not need servicing. However, periodic charging of the battery with an automotive type battery charger will extend its life. • Keep battery and terminals clean. • Keep battery bolts tight. • See chart for charging times. 2. Disconnect BLACK battery cable then RED battery cable. 3. Carefully remove the battery from the mower 4. Rinse the battery with plain water and dry. 5. Clean terminals and battery cable ends with a wire brush until shiny. 6. Coat the terminals with grease or petroleum jelly. Replacing battery 1. Install the new battery. 2. Connect RED battery cable first to positive (+) battery terminal. 3. Connect BLACK grounding cable to negative (-) battery terminal. 4. Slide mount bracket back up over battery and tighten nuts. 5. Replace terminal boot cover. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

23
MAINTENANCE
Battery
If the battery is too weak to start the engine, it
must be recharged.
Jumper Cable Use
1.
Connect each end of the RED cable to the
POSITIVE (+) terminal on each battery, taking
care not to short against chassis.
2.
Connect one end of the BLACK cable to the
NEGATIVE (-) terminal of the fully charged
battery.
3.
Connect the other end of the BLACK cable
to a good CHASSIS GROUND on the mower
with the discharged battery, away from the
fuel tank and battery.
To remove cables, reverse order
1.
Remove BLACK cable first from chassis and
then from the fully charged battery.
2.
Remove RED cable last from both batteries.
The mower is equipped with a maintenance
free battery and does not need servicing.
However, periodic charging of the battery with an
automotive type battery charger will extend its life.
• Keep battery and terminals clean.
• Keep battery bolts tight.
• See chart for charging times.
STD
BATTERY
STATE
OF
CHARGE
APPROXIMATE CHARGING TIME*
TO FULL CHARGE AT 80
O
F
Maximum Rate at:
50 Amps
30 Amps
20 Amps
10 Amps
12.6V
100%
- FULL CHARGE -
12.4V
75%
20 min.
35 min.
48 min.
90 min.
12.2V
50%
45 min.
75 min.
95 min.
180 min.
12.0V
25%
65 min.
115 min.
145 min.
280 min.
11.8V
0%
85 min.
150 min.
195 min.
370 min.
*Charging time depends on battery capacity,
condition, age, temperature and efficiency of charger
Cleaning battery and terminals
Corrosion and dirt on the battery and terminals
can cause the battery to lose power.
1.
Loosen the two nuts attached to the side
J bolts just enough that the battery mount
bracket slides down off the battery.
2.
Disconnect BLACK battery cable then RED
battery cable.
3.
Carefully remove the battery from the mower
4.
Rinse the battery with plain water and dry.
5.
Clean terminals and battery cable ends with a
wire brush until shiny.
6.
Coat the terminals with grease or petroleum
jelly.
Replacing battery
1. Install the new battery.
2.
Connect RED battery cable first to positive (+)
battery terminal.
3.
Connect BLACK grounding cable to negative
(-) battery terminal.
4.
Slide mount bracket back up over battery and
tighten nuts.
5. Replace terminal boot cover.
IMPORTANT INFORMATION
Do not open
or remove battery caps or covers. Adding or
checking level of electrolyte is not necessary.
Always use two wrenches for the terminal
screws.
CAUTION!
Lead-acid batteries generate
explosive gases. Keep sparks, flame and
smoking materials away from batteries. Always
wear eye protection when around batteries.