Husqvarna Z554L Owner Manual - Page 21
Warning, Caution, Important Information
View all Husqvarna Z554L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
MAINTENANCE MAINTENANCE DAILY BEFORE AFTER AT LEAST ONCE EACH YEAR MAINTENANCE INTERVAL IN HOURS 50 250 500 CHECK Throttle and choke cables for adjustment Mower deck for adjustment Condition of belts, belt pulleys Caster wheels (every 200 hours) Hydraulic oil level Engine valve clearance 3) CHANGE Spark plugs Engine oil 1) Engine oil filter Fuel filter Paper air filter 2) Air cleaner foam pre-filter 2) Air cleaner paper filter cartridge 2) Hydraulic oil (every 400 hours) Hydraulic oil filter (every 400 hours) ALSO Dismantle and inspect starter 3) (every 500 hours) Perform the 500-hour service 3) ■ ● ● ● ♦ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ● ● ● ● ♦ ♦ ♦ ● = Described in this manual ♦ = Not described in this manual ■ = Refer to the engine manufacturer's manual 1) First change after 8-10 hours. When operating with a heavy load or at high ambient temperatures, replace every 50 hours. 2) In dusty conditions, cleaning and replacement are required more often. 3) Performed by authorized service workshop. WARNING! Do not short battery terminals by allowing a wrench or other objects to contact the two terminals at the same time. Before connecting battery, remove metal bracelets, wristwatch bands, rings, etc. Positive terminal must be connected first to prevent sparks from accidental grounding. IMPORTANT INFORMATION The mower is equipped with a 12-volt negative grounded system. The other vehicle must also be a 12volt negative grounded system. Do not use the mower to start other vehicles. CAUTION! Always wear eye protection when around batteries. 21