IBM 3580-H23 Setup Guide - Page 55
On the leader pin, and the cartridge aside.
View all IBM 3580-H23 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
2. To find the end of the tape inside the cartridge, attach the cartridge manual rewind tool ( 1 in Figure 18) to the cartridge's hub 2 by fitting the tool's teeth between the teeth of the hub. Turn the tool clockwise until you see the end of the tape inside the cartridge. Then, slowly turn the rewind tool counterclockwise to bring the tape edge toward the cartridge door 3 . 3. Continue to turn the rewind tool counterclockwise until approximately 13 cm (5 in.) of tape hangs from the cartridge door. If necessary, grasp the tape and pull gently to unwind it from the cartridge. 4. Remove the rewind tool by pulling it away from the cartridge. Set the tool and the cartridge aside. Figure 18. Winding the tape out of the cartridge. Turn the cartridge manual rewind tool clockwise to see the end of the tape, then turn it counterclockwise to bring the tape to the cartridge door. 5. On the leader pin ( 1 in Figure 19), locate the open side of the C-clip 2 . The C-clip is a small black part that secures the tape 3 to the pin. 6. Remove the C-clip from the leader pin by using your fingers to push the clip away from the pin. Set the pin aside and discard the clip. 3 1 2 Figure 19. Removing the C-clip from the leader pin. Use your fingers to push the C-clip from the leader pin. Chapter 4. Using Ultrium Media 39 A67E0036