IBM 3580-L23 Setup Guide - Page 98
Table 8 on To clear the error, turn the power off, then on again.
View all IBM 3580-L23 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Maint Mode: Select Exit Maint Mode followed by: Ultrium Tape Drive Drive Empty v If no error is detected, 0 temporarily appears in the single-character display, then goes blank. The drive then exits maintenance mode. v If an error is detected, the single-character display shows an error code but still exits maintenance mode. To determine the error, locate the code in Table 8 on page 55. To clear the error, turn the power off, then on again. The 3580 Ultrium 2 Tape Drive also exits maintenance mode automatically after it completes a maintenance function or after 10 minutes if no action has occurred. 82 IBM 3580 Ultrium Tape Drive Setup and Operator Guide
Maint Mode: Select
Exit Maint Mode
followed by:
Ultrium Tape Drive
Drive Empty
v
If no error is detected,
0
temporarily appears in the single-character display,
then goes blank. The drive then exits maintenance mode.
v
If an error is detected, the single-character display shows an error code but
still exits maintenance mode. To determine the error, locate the code in
Table 8 on page 55.
To clear the error, turn the power off, then on again.
The 3580 Ultrium 2 Tape Drive also exits maintenance mode automatically after it
completes a maintenance function or after 10 minutes if no action has occurred.
82
IBM 3580 Ultrium Tape Drive Setup and Operator Guide