Boot Fail Count, Start Options, Enabled, Disabled

Page 54 highlights

1-4-3 2-1-1 2-1-2 2-1-3 2-1-4 2-2-1 2-2-2 2-2-3 2-2-4 2-3-1 2-3-2 2-3-3 2-3-4 2-4-1 3-1-1 3-1-2 3-1-3 3-1-4 3-2-1 3-2-2 3-2-4 3-3-1 3-3-2 3-3-3 Interrupt vector loading test has failed. Secondary DMA register test has failed. Primary DMA register test has failed. Primary interrupt mask register test has failed. Secondary interrupt mask register test has failed. Interrupt vector loading has failed. Keyboard controller test has failed. CMOS power failure and checksum checks have failed. CMOS configuration information validation has failed. Screen initialization has failed. Screen memory test has failed. Screen retrace tests have failed. Search for video ROM has failed. Screen test indicates the screen is operable. Timer tick interrupt test has failed. Interval timer channel 2 test has failed. RAM test has failed above address hex 0FFFF. Time-of-Day clock test has failed. Serial port test has failed. Parallel port test has failed. Comparison of CMOS memory size against actual has failed. A memory size mismatch has occurred. I2C bus has failed. No memory has been detected in the server. Call for service. Turn off the server, unplug all power cords, and reconnect all power cords; then, restart the server. If the problem remains, call for service. Call for service. Reseat the memory modules or install a memory module. If the problem remains, call for service. Turn off the server, unplug all power cords, and reconnect all power cords; then, restart the server. If the problem remains, call for service. Reseat the memory modules or install a memory module. If the problem remains, call for service. Note: In some memory configurations, the 3-3-3 beep code might sound during POST followed by a blank display screen. If this occurs and the Boot Fail Count feature in the Start Options of the Configuration/Setup Utility is set to Enabled (its default setting), you must restart the server three times to force the system BIOS code to reset the memory connector or bank of connectors from Disabled to Enabled. 42 IBM xSeries 335 Type 8676: Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

1-4-3
Interrupt vector loading test has failed.
Call for service.
2-1-1
Secondary DMA register test has failed.
2-1-2
Primary DMA register test has failed.
2-1-3
Primary interrupt mask register test has failed.
2-1-4
Secondary interrupt mask register test has failed.
2-2-1
Interrupt vector loading has failed.
2-2-2
Keyboard controller test has failed.
2-2-3
CMOS power failure and checksum checks have failed.
2-2-4
CMOS configuration information validation has failed.
2-3-1
Screen initialization has failed.
Turn off the server, unplug all power
cords, and reconnect all power cords;
then, restart the server. If the problem
remains, call for service.
2-3-2
Screen memory test has failed.
Call for service.
2-3-3
Screen retrace tests have failed.
2-3-4
Search for video ROM has failed.
2-4-1
Screen test indicates the screen is operable.
3-1-1
Timer tick interrupt test has failed.
3-1-2
Interval timer channel 2 test has failed.
3-1-3
RAM test has failed above address hex 0FFFF.
3-1-4
Time-of-Day clock test has failed.
3-2-1
Serial port test has failed.
3-2-2
Parallel port test has failed.
3-2-4
Comparison of CMOS memory size against actual has
failed.
3-3-1
A memory size mismatch has occurred.
Reseat the memory modules or install a
memory module. If the problem remains,
call for service.
3-3-2
I
2
C bus has failed.
Turn off the server, unplug all power
cords, and reconnect all power cords;
then, restart the server. If the problem
remains, call for service.
3-3-3
No memory has been detected in the server.
Reseat the memory modules or install a
memory module. If the problem remains,
call for service.
Note:
In some memory configurations,
the 3-3-3 beep code might sound during
POST followed by a blank display screen.
If this occurs and the
Boot Fail Count
feature in the
Start Options
of the
Configuration/Setup Utility is set to
Enabled
(its default setting), you must
restart the server three times to force the
system BIOS code to reset the memory
connector or bank of connectors from
Disabled
to
Enabled
.