IBM 887022X User Manual - Page 70

Utility, Configuration, Settings, Modem, Dedicated, Disabled, Enabled

Page 70 highlights

10. Use the arrow keys to select Exit Utility from the menu or press Esc to close the Utility program. 11. Remove the diskette from the server. The server restarts automatically. 12. If you also want to configure the management port, continue with "Configuring the management port for text-based remote access." Otherwise, go to "Installing Advanced System Management device drivers" on page 61. Configuring the management port for text-based remote access: Complete the following steps to configure the Remote Supervisor Adapter management port for access using a modem or null modem. If you completed the procedure for configuring the Ethernet port and the Configuration Settings window is open, start with step 3. 1. With the server turned off, insert the diskette with the downloaded utility program into the diskette drive; then, turn on the server. The utility starts automatically, displaying the Remote Supervisor Utility window. 2. Use the arrow keys to select Configuration Settings; then, press Enter. The Configuration Settings window opens. 3. Use the arrow keys to select Modem Settings; then, press Enter. The Modem Settings window opens, as shown in the following illustration. Note: The values in the window are only examples; your settings might be different. Figure 23. Ethernet Settings window with text-based remote access values 4. Verify the following management port values: Baud Rate The default is 57600. Make sure that the baud rate matches the baud rate of the device you are connecting to the management port on the Remote Supervisor Adapter. Dedicated to ASM The default is Disabled. If you are using point-to-point protocol (PPP), set this field to Enabled. If the value in this field is Enabled when the server is restarted, the management port remains dedicated to system management and is not returned to the operating system. 58 xSeries 445 Type 8870: User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98

10.
Use
the
arrow
keys
to
select
Exit
Utility
from
the
menu
or
press
Esc
to
close
the
Utility
program.
11.
Remove
the
diskette
from
the
server.
The
server
restarts
automatically.
12.
If
you
also
want
to
configure
the
management
port,
continue
with
“Configuring
the
management
port
for
text-based
remote
access.”
Otherwise,
go
to
“Installing
Advanced
System
Management
device
drivers”
on
page
61.
Configuring
the
management
port
for
text-based
remote
access:
Complete
the
following
steps
to
configure
the
Remote
Supervisor
Adapter
management
port
for
access
using
a
modem
or
null
modem.
If
you
completed
the
procedure
for
configuring
the
Ethernet
port
and
the
Configuration
Settings
window
is
open,
start
with
step
3.
1.
With
the
server
turned
off,
insert
the
diskette
with
the
downloaded
utility
program
into
the
diskette
drive;
then,
turn
on
the
server.
The
utility
starts
automatically,
displaying
the
Remote
Supervisor
Utility
window.
2.
Use
the
arrow
keys
to
select
Configuration
Settings
;
then,
press
Enter.
The
Configuration
Settings
window
opens.
3.
Use
the
arrow
keys
to
select
Modem
Settings
;
then,
press
Enter.
The
Modem
Settings
window
opens,
as
shown
in
the
following
illustration.
Note:
The
values
in
the
window
are
only
examples;
your
settings
might
be
different.
4.
Verify
the
following
management
port
values:
Baud
Rate
The
default
is
57600.
Make
sure
that
the
baud
rate
matches
the
baud
rate
of
the
device
you
are
connecting
to
the
management
port
on
the
Remote
Supervisor
Adapter.
Dedicated
to
ASM
The
default
is
Disabled
.
If
you
are
using
point-to-point
protocol
(PPP),
set
this
field
to
Enabled
.
If
the
value
in
this
field
is
Enabled
when
the
server
is
restarted,
the
management
port
remains
dedicated
to
system
management
and
is
not
returned
to
the
operating
system.
Figure
23.
Ethernet
Settings
window
with
text-based
remote
access
values
58
xSeries
445
Type
8870:
User’s
Guide