Icom IC-7850 Instruction Manual - Page 227

Screen Capture Keyboard [Print Screen], Screen Capture [POWER] SW

Page 227 highlights

Previous view SET MODE 15 ■ Others set mode (continued) Keyboard [F1]-[F8] (KEYER) (Default: OFF) Enables keyer memory transmission using a keyboard connected to [USB A]. • OFF: Turn OFF the function. • ON: Pushing one of [F1] to [F8] on the keyboard, transmits the programmed keyer memory. Holding down [SHIFT] and pushing one of [F1] to [F8] on the keyboard repeatedly transmits memory. Screen Capture [POWER] SW (Default: OFF) Turns the Print Screen function ON or OFF. • OFF: Turn OFF the function. • ON: Prints the screen when [POWER] is pushed. Screen Capture Keyboard [Print Screen]  (Default: OFF) Enables the printing screen using a keyboard connected to [USB A]. • OFF: Turn OFF the function. • ON: Prints the screen when the [Print Screen] key on the connected keyboard is pushed. Screen Capture Storage Media  (Default: SD CARD) Select the media storage for the captured screen. • Options: S D CARD or USB flash drive. Screen Capture Data Format (Default: PNG) Select the data format for the captured screen. • Options: P NG or BMP Shutdown Function (Default: Shutdown) Selects the shutdown option. • Shutdown: Shuts down right after [POWER] has been held down for 1 second. • Standby/Shutdown: Enters the remote standby mode. If the remote standby mode is selected, the IC-7850 can be remotely turned ON later using the optional RS-BA1. 【When "Standby/Shutdown" is selected】 qHold down [POWER] for approximately for 1 second to turn OFF the power. •The shutdown option dialogue appears. w S elect the shutdown option using [Ù](F) or [Ú](F). •If you want to turn OFF the power immediately, select "Shutdown." •If you want to remotely turn ON the power later, select "Standby (for Remote Control)." *The power indicator, which is located on the right above [POWER], slowly blinks Orange. The cooling fan still rotates. ePush [POWER]. CI-V Baud Rate (Default: Auto) Selects the CI-V data transfer rate. • Options: 4 800, 9600, 19200(bps) and Auto When "Auto" is selected, the baud rate is automatically set, according to the data rate of the connected controller. CI-V Address (Default: 8Eh) Selects the CI-V address. • Range: 02h-8Eh-DFh "8Eh" is the default address of IC-7850. CI-V Transceive Turns the Transceive function ON or OFF. • OFF: Turn the function OFF. • ON: Turn the function ON. (Default: ON) CI-V USB/LANREMOTE Transceive Address  (Default: 00h) Sets the address used to remotely control the transceiver/ receiver, through [USB B] or [LAN]. The control signal is output from [REMOTE]. • Range: 0 0h-DFh When multiple equipment are connected: The default transceive address is "00h." To control dedicated equipment (example IC-PW1) when several equipment are connected, match the same CI-V address. 15-17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278

15-17
15
SET MODE
Others set mode (continued)
Keyboard [F1]–[F8] (KEYER)
(Default:
OFF
)
Enables keyer memory transmission using a keyboard
connected to [USB A].
• OFF:
Turn OFF the function.
• ON:
Pushing one of [F1] to [F8] on the keyboard,
transmits the programmed keyer memory.
Holding down [SHIFT] and pushing one of [F1]
to [F8] on the keyboard repeatedly transmits
memory.
Screen Capture [POWER] SW
(Default:
OFF
)
Turns the Print Screen function ON or OFF.
• OFF:
Turn OFF the function.
• ON:
Prints the screen when [POWER] is pushed.
Screen Capture Keyboard [Print Screen]
(Default:
OFF
)
Enables the printing screen using a keyboard connected
to [USB A].
• OFF:
Turn OFF the function.
• ON:
Prints the screen when the [Print Screen] key on
the connected keyboard is pushed.
Screen Capture Storage Media
(Default:
SD CARD
)
Select the media storage for the captured screen.
• Options: SD CARD or USB flash drive.
Screen Capture Data Format
(Default:
PNG
)
Select the data format for the captured screen.
• Options: PNG or BMP
Shutdown Function
(Default:
Shutdown
)
Selects the shutdown option.
• Shutdown:
Shuts down right after [POWER]
has been held down for
1 second.
• Standby/Shutdown:
Enters the remote
standby
mode.
If the remote standby mode is
selected, the IC-7850 can be
remotely turned ON later using
the optional RS-BA1.
When "Standby/Shutdown" is selected
q
Hold down [POWER] for approximately for 1 second to
turn OFF the power.
•The shutdown option dialogue appears.
w
Select the shutdown option using [
Ù
](F) or [
Ú
](F).
•If you want to turn OFF the power immediately, select
"Shutdown."
•If you want to remotely turn ON the power later, select
"Standby (for Remote Control)."
*The power indicator, which is located on
the right
above [POWER], slowly blinks Orange.
The cooling fan still rotates.
e
Push [POWER].
CI-V Baud Rate
(Default:
Auto
)
Selects the CI-V data transfer rate.
• Options: 4800, 9600, 19200(bps) and Auto
When “Auto” is selected, the baud rate is automatically
set, according to the data rate of the connected
controller.
CI-V Address
(Default:
8Eh
)
Selects the CI-V address.
• Range:
02h–8Eh–DFh
"8Eh" is the default address of IC-7850.
CI-V Transceive
(Default:
ON
)
Turns the Transceive function ON or OFF.
• OFF:
Turn the function OFF.
• ON:
Turn the function ON.
CI-V USB/LAN
REMOTE Transceive Address
(Default:
00h
)
Sets the address used to remotely control the transceiver/
receiver, through [USB B] or [LAN]. The control signal is
output from [REMOTE].
• Range: 00h–DFh
When multiple equipment are connected:
The default transceive address is "00h."
To control dedicated equipment (example IC-PW1) when
several equipment are connected, match the same CI-V
address.