Intel AXXRMS2AF080 Hardware User Guide - Page 32

Fault Tolerance, Table 6. Fault Tolerance Features

Page 32 highlights

Specification Flexibility Background services Cache policy Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 • Drive migration • RAID level migration • Drive Roaming • Online Capacity Expansion - without reboot • Rebuild • Consistency Check • Migration • OCE • Patrol Read • Write-through • Normal Read • Direct I/O Fault Tolerance Table 6. Fault Tolerance Features Specification Self Monitoring Analysis and Reporting Technology (SMART) support Drive Replacement Drive Rebuild Using Hot Spares Error Checking and Indication Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and drive electronics. • Auto detection of failure • Hot-plug • Hot-swap • Automatic at fail • Dedicated per Array • Global for any array • Auto-resume of initialization or rebuild on reboot • Parity generation and checking, automatic consistency checking • Patrol reads • Activity and fault LEDs • Multiple retries • Logs in NVRAM, event log, CIM, Smart, Intel® RAID Web Console 2 22 Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

22
Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide
Fault Tolerance
Table 6. Fault Tolerance Features
Flexibility
Drive migration
RAID level migration
Drive Roaming
Online Capacity Expansion - without reboot
Background services
Rebuild
Consistency Check
Migration
OCE
Patrol Read
Cache policy
Write-through
Normal Read
Direct I/O
Specification
Intel
®
Integrated RAID Module RMS2AF040 and
RMS2AF080
Specification
Intel
®
Integrated RAID Module RMS2AF040 and
RMS2AF080
Self Monitoring Analysis and
Reporting Technology (SMART)
support
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors, heads,
and drive electronics.
Drive Replacement
Auto detection of failure
Hot-plug
Hot-swap
Drive Rebuild Using Hot Spares
Automatic at fail
Dedicated per Array
Global for any array
Auto-resume of initialization or rebuild on reboot
Error Checking and Indication
Parity generation and checking, automatic consistency
checking
Patrol reads
Activity and fault LEDs
Multiple retries
Logs in NVRAM, event log, CIM, Smart, Intel
®
RAID
Web Console 2