Intel AXXRMS2AF080 Hardware User Guide - Page 35

RAID Physical Drive Status

Page 35 highlights

3. The RAID firmware presents the virtual drive to the operating system. RAID Physical Drive Status Table 7. RAID Physical Drive Status Drive State Unconfigured Good Online Hot Spare Failed Rebuilding Unconfigured Bad Missing Offline None Code Unconfigured Good ONLN HOTSP FAILED REBUILD Unconfigured Bad Missing Offline None Description The drive is functioning normally, but is not part of a configured virtual drive and is not a hot spare. The drive is online, is part of a configured virtual drive, and is functioning normally. A physical drive that is configured as a hot spare. A physical drive that was originally configured as Online or Hot Spare, but on which the firmware detects an unrecoverable error. A physical drive to which data is being written to restore full redundancy for a virtual drive. A physical drive on which the firmware detects an unrecoverable error; the physical drive was Unconfigured Good or the physical drive could not be initialized. A physical drive that was online, but which has been removed from its location. A physical drive that is part of a virtual drive but which has invalid data as far as the RAID configuration is concerned. A physical drive with an unsupported flag set. An Unconfigured Good or Offline physical drive that has completed the 'prepare for removal' operation. RAID Virtual Drive Status Table 8. RAID Virtual Drive Status Drive State Optimal Degraded Code Optimal Degraded Offline Offline Description The drive operating system is good. All configured drives are online. The drive operating condition is not optimal because one of the configured drives has failed or is offline. The drive is not available to the operating system and is unusable. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User's Guide 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide
25
3.
The RAID firmware presents the virtual drive to the operating system.
RAID Physical Drive Status
Table 7. RAID Physical Drive Status
RAID Virtual Drive Status
Table 8. RAID Virtual Drive Status
Drive State
Code
Description
Unconfigured Good
Unconfigured Good
The drive is functioning normally, but is not part
of a configured virtual drive and is not a hot
spare.
Online
ONLN
The drive is online, is part of a configured virtual
drive, and is functioning normally.
Hot Spare
HOTSP
A physical drive that is configured as a hot spare.
Failed
FAILED
A physical drive that was originally configured as
Online or Hot Spare, but on which the firmware
detects an unrecoverable error.
Rebuilding
REBUILD
A physical drive to which data is being written to
restore full redundancy for a virtual drive.
Unconfigured Bad
Unconfigured Bad
A physical drive on which the firmware detects
an unrecoverable error; the physical drive was
Unconfigured Good or the physical drive could
not be initialized.
Missing
Missing
A physical drive that was online, but which has
been removed from its location.
Offline
Offline
A physical drive that is part of a virtual drive but
which has invalid data as far as the RAID
configuration is concerned.
None
None
A physical drive with an unsupported flag set. An
Unconfigured Good or Offline physical drive that
has completed the 'prepare for removal'
operation.
Drive State
Code
Description
Optimal
Optimal
The drive operating system is good. All config-
ured drives are online.
Degraded
Degraded
The drive operating condition is not optimal
because one of the configured drives has failed
or is offline.
Offline
Offline
The drive is not available to the operating system
and is unusable.