Intel SBXL52 Hardware Maintenance Manual - Page 102
Start the Configuration/Setup Utility program.
View all Intel SBXL52 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
✏ NOTE See "System" on page 104 to determine which components should be replaced by a field service technician. Memory problems Symptom FRU/action The amount of system memory displayed is less than the amount of physical memory installed. 1. Verify that: • The memory modules are seated properly. • You have installed the correct type of memory. • If you changed the memory, you updated the memory configuration with the Configuration/Setup Utility program. • All banks of memory on the DIMMs are enabled. The computer might have automatically disabled a DIMM bank when it detected a problem or a DIMM bank could have been manually disabled. 2. Check POST error log for error message 289: • If the DIMM was disabled by a system-management interrupt (SMI), replace the DIMM. • If the DIMM was disabled by the user or by POST: a. Start the Configuration/Setup Utility program. b. Enable the DIMM. c. Save the configuration and restart the computer. 3. DIMM. 4. System board. ✏ NOTE See "System" on page 104 to determine which components should be replaced by a field service technician. Microprocessor problems Symptom FRU/action The blade server emits a continuous tone during POST. (The startup (boot) microprocessor is not working properly.) 1. Verify that the startup microprocessor is seated properly. 2. Startup microprocessor. 88 SBXL52: Hardware Maintenance Manual and Troubleshooting Guide