Kodak 1012434 User Manual - Page 115

Vacuuming the scanner, Cleaning the imaging area

Page 115 highlights

5. Replace the core assembly in the feed module. You may need to slide the shaft to the right or left so the core fits properly within the feed module housing. Vacuuming the scanner Cleaning the imaging area Slide shaft 6. Repeat the replacement procedure outlined above for the other core assembly. 7. Reinstall the feed module. 8. Reinstall the feed module cover by aligning the tabs in the slots and pushing the feed module cover down until it snaps into place. Before cleaning the imaging area, it is suggested that you vacuum the inside of the scanner to remove any dust and debris. 1. Remove dust and debris from this area by using a Staticide wipe. Be careful not to scratch the imaging area when cleaning. IMPORTANT: Staticide wipes contain isopropanol which can cause eye irritation and dry skin. Wash your hands with soap and water after performing maintenance procedures. Refer to the MSDS for more information. 2. Wipe the upper and lower imaging area again with an almost-dry Staticide wipe to remove any streaks. 3. When finished, close the scanner cover. A-61560 January 2007 111

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

A-61560
January 2007
111
5.
Replace the core assembly in the feed module. You may need to
slide the shaft to the right or left so the core fits properly within the
feed module housing.
6.
Repeat the replacement procedure outlined above for the other core
assembly.
7.
Reinstall the feed module.
8.
Reinstall the feed module cover by aligning the tabs in the slots and
pushing the feed module cover down until it snaps into place.
Vacuuming the scanner
Before cleaning the imaging area, it is suggested that you vacuum the
inside of the scanner to remove any dust and debris.
Cleaning the imaging
area
1.
Remove dust and debris from this area by using a Staticide wipe. Be
careful not to scratch the imaging area when cleaning.
IMPORTANT: Staticide wipes contain isopropanol which can cause eye
irritation and dry skin. Wash your hands with soap and
water after performing maintenance procedures. Refer to
the MSDS for more information.
2.
Wipe the upper and lower imaging area again with an almost-dry
Staticide wipe to remove any streaks.
3.
When finished, close the scanner cover.
Slide shaft