Kodak ATS Operation Manual - Page 25

Maintenance, Projection Lamps, Lamp Tips

Page 25 highlights

Maintenance To ensure a long life and trouble-free operation for your projector: • Allow the air to flow freely around the projector. • Do not recirculate warm air. • Keep the projector dust free. • If your projector is chilled, bring it to room temperature before operating. Projection Lamps Quartz-halogen 82 V projection lamps- Included: EXR, 300 W (35-hour lamp life at full lamp/medium-brightness) Sampling of other lamps: EXY (200 hours/less brightness) EXW (15 hours/maximum brightness) FHS (70 hours/medium brightness) Use combinations of lamp brightness, plus half- and full-lamp settings to approximate image brightness in multi-projector presentations. Lamp Tips Desired Brightness Maximum High Medium Low EKTAGRPAHIC III Projector Lamp EXW EXR FHS EXY • Projector operation on line voltages above 125 volts greatly reduces the lamp life. • Unplug the projector before changing the lamp. • Allow for unrestricted flow of air to the exhaust vent to prolong lamp life. • Gently wipe off any fingerprints with a soft cloth moistened with rubbing alcohol. KODAK EKTAGRAPHIC III Slide Projector 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

KODAK EKTAGRAPHIC III Slide Projector
21
Maintenance
To ensure a long life and trouble-free operation for your projector:
Allow the air to flow freely around the projector.
Do not recirculate warm air.
Keep the projector dust free.
• If your projector is chilled, bring it to room temperature before operating.
Projection Lamps
Quartz-halogen 82 V projection lamps
Included: EXR, 300 W
(35-hour lamp life at full lamp/medium-brightness)
Sampling of other lamps:
EXY (200 hours/less brightness)
EXW (15 hours/maximum brightness)
FHS (70 hours/medium brightness)
Use combinations of lamp brightness, plus half- and full-lamp settings to
approximate image brightness in multi-projector presentations.
Lamp Tips
Projector operation on line voltages above 125 volts greatly
reduces the lamp life.
Unplug the projector before changing the lamp.
Allow for unrestricted flow of air to the exhaust vent to prolong
lamp life.
Gently wipe off any fingerprints with a soft cloth moistened with
rubbing alcohol.
Desired
Brightness
EKTAGRPAHIC III
Projector Lamp
Maximum
EXW
High
EXR
Medium
FHS
Low
EXY